Descargar Imprimir esta página

Product Description And Specifications - Fein GAL 1880 CV Manual De Instrucciones

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 24
If the plug is not suitable for your socket outlets,
it should be cut off and an appropriate plug fitted
in its place by an authorised customer service
agent. The replacement plug should have the
same fuse rating as the original plug.
The severed plug must be disposed of to avoid a
possible shock hazard and should never be inser-
ted into a mains socket elsewhere.
Do not operate the charger in closed cup-
u
boards or near sources of heat.Otherwise,
the charger may overheat and no longer func-
tion properly.
When it is not in use for a long period, re-
u
move the battery from the charger and pull
out the plug. Saving energy protects the en-
vironment.
Remove the charger's plug from the plug
u
socket when carrying out cleaning. There is
a risk of electric shock.
Do not screw or nail any signs or labels
u
onto the charger. Damaged insulation offers
no protection against electric shocks. Use
stick-on labels instead.
Product description and
specifications
English
Intended use
English
The battery charger is intended for charging the
rechargeable FEIN AMPShare Li-Ion batteries or
those of the AMPShare partners.
Product features
English
The numbering of the components shown refers
to the diagram of the charger on the graphics
page.
(1) Charging bay
(2) Cord wrap
(3) Green battery charge level indicator
(4) Red battery charge level indicator
Technical data
English
Battery charger
Article number
Battery charging
voltage (auto-
matic voltage de-
tection)
Charging cur-
A)
rent
GAL 1880 CV
9 26 04 332 00 0
9 26 04 333 00 0
9 26 04 335 00 0
V
A
Battery charger
Permitted battery
temperature dur-
ing charging
ProCORE18V bat-
teries...: Charging
time at battery
capacity approx.
– 4.0 Ah
– 8.0 Ah
– 12.0 Ah
Standard batter-
ies: Charging time
at battery capa-
A)
city, approx.
– 2.0 Ah
– 4.0 Ah
– 5.0 Ah
Number of bat-
tery cells
Weight according
to EPTA-Proced-
ure 01:2014
Protection class
A) Depends on temperature and rechargeable battery
type
B) State of charge of the battery is approx. 80%. The bat-
tery can be removed for immediate use.
C) State of charge of the battery is 95 %–100 %.
Operation
Start-up
English
Note the mains voltage! The voltage of the
u
power source must match the voltage spe-
cified on the rating plate of the charger. Char-
gers marked with 230 V can also be operated
with 220 V.
Charging process
The charging process begins as soon as the
mains plug for the charger is inserted into the
mains socket and the battery is inserted into the
charging slot (1).
Thanks to the intelligent charging process, the
charge condition of the battery is automatically
detected and then charged up with the optimal
charge current depending on battery temperat-
18
ure and voltage.
In this way, the battery is treated with care and
remains permanently fully charged when it is
stored in the charger.
8.0
GAL 1880 CV
°
C
(80 %
A)
min
min
min
(80 %
min
min
min
kg
English
English
en
 9
0–45
B)
) / battery
C)
charged
32 / 51
68 / 79
113 / 126
B)
) / battery
C)
charged
15 / 30
25 / 35
35 / 45
5–15
0.66
/ II

Publicidad

loading

Este manual también es adecuado para:

9 26 04 332 00 09 26 04 333 00 09 26 04 335 00 0