17. Multiplier
This screen indicates Multiplier type connected in
the tool. Press
to select type. Press
18. Accumulated Count
This screen indicates totally accumulated count in
the tool.
19. Shunt Value & Wireless Mode
Left screen indicates Shunt value.
Right screen indicates wireless mode in the tool.
Troubleshooting
Code
Description
E001
Over current
E002
Low Battery
E003
Battery
overheating
E004
Battery low
temp
E005
Electric
overheating
Note: if troubleshooting doesn't work, call authorised service centre.
1.
1English1
to enter EDIT mode. Press
to SAVE and EXIT.
Troubleshooting
Detach and
reinstall battery
Change battery
Cool down or
change battery
Warm up or
change battery
Cool tool down
English
/
Code
Description
E006
Electric short
E007
Motor stall
E008
Motor
overheating
E009
Strain gauge
fault
-17
Troubleshooting
Call service
centre
Detach and
reinstall battery
Cool tool down
Call service
centre