Descargar Imprimir esta página

Detection Range; Regulatory Information - CADDX Plus Serie Instrucciones De Instalación

Publicidad

(8) Clamp
(9) Area for mounting the VVT705 test transmitter
(10) Fixing bolt
(11) Mounting plate VVM300
(12) Expander bolt
(13) Test transmitter VVT705
Using the mounting plate VVM300 as a template
A
Holes for VVS300/320 Plus and VVS302/322 Plus
B
Holes for Securitas SSD70
C
Holes for Cerberus Alarmcom detectors
D
Hole for expansion plug or recess mounting box
E
Holes for Securitas 2000
F
Template and mounting holes for test transmitter VVT705
G
Holes for accessories.
Figure 4: Mounting the detector directly on a metal surface
without using a mounting plate
Figure 5: Mounting the detector on a metal surface using the
VVM304 weld-on plate
First weld points 1, 2, 3, and 4. Then weld seams 5 and 6.
Figure 6: Mounting on concrete
Always use a VVM300 mounting plate. The expansion plug
must penetrate at least 50 mm into the concrete. Please follow
the steps shown in Figure 6 if you are installing the test
transmitter VVT705.
Note:
For the equipment to conform to CEI standard 79-2, the
VVT705 test transmitter must be installed.
Figure 7: Control and function test
Using a voltmeter, check the background signal level in the
detector to prevent nuisance alarms. Set the sensitivity to
Gmax during the test.
VVS300/320 Plus
VVS302/322 Plus
0.7 V
0 V
1.4 V
2 V
Note:
Try to remove the source of ambient noise instead of
reducing the range.
Functional testing with hand tester VVT310 (1) and mechanical
tool (2):
VVS300/320 Plus: Alarm in 60 s. Alarm after 5 blows.
VVS302/322 Plus: Alarm in 45 s.

Detection range

Table 1: Detection range (in meters)
Material
Sensitivity
setting
Concrete
Steel
1/Gmax
Brick
Concrete
Steel
2/Gref
Brick
Concrete
Steel
3/Gmin
Brick
P/N 1038579 (ML) • REV E • ISS 16FEB21
Measure
None
Reduce range/remove
source
Thermal
Diamond
Drilling
lance
disk
4
14
14
8
14
14
3
8
8
3
9
9
4
9
9
1
6
6
2
6
6
2
6
6
4
4
Material
Sensitivity
setting
Concrete
Steel
4
Brick
Concrete
Steel
5
Brick
Specifications
Input power
9 to 15 V DC, 2 V max. ripple pp
Current consumption
8.6 mA nom.
Alarm output
Form A solid state relay, series resistance
35 Ω max.
Alarm indication
LED-ind. output 3
Sensitivity
5 steps of 6 dB each
Range
See Table 1 above
Temp. 84°C, drill shield, opening/pry-off
Sabotage protection
contact
Low voltage alarm
7.5 V
−20 to +55°C
Temperature limits
Dimensions
100 x 80 x 33 mm
Colour
Teknos BE 8086 (grey)
Weight
390 g

Regulatory information

PLACED ON THE MARKET BY:
Manufacturer
Carrier Fire & Security Americas Corporation Inc.
13995 Pasteur Blvd
Palm Beach Gardens, FL 33418, USA
AUTHORIZED EU REPRESENTATIVE:
Carrier Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Product warnings
THESE PRODUCTS ARE INTENDED FOR SALE
and disclaimers
TO AND INSTALLATION BY QUALIFIED
PROFESSIONALS. CARRIER FIRE &
SECURITY CANNOT PROVIDE ANY
ASSURANCE THAT ANY PERSON OR ENTITY
BUYING ITS PRODUCTS, INCLUDING ANY
"AUTHORIZED DEALER" OR "AUTHORIZED
RESELLER", IS PROPERLY TRAINED OR
EXPERIENCED TO CORRECTLY INSTALL FIRE
AND SECURITY RELATED PRODUCTS.
For more information on warranty disclaimers and
product safety information, please check
https://firesecurityproducts.com/policy/product-
warning/
REACH
Product may contain substances that are also
Candidate List substances in a concentration
above 0.1% w/w, per the most recently published
Candidate List found at ECHA Web site.
Safe use information can be found at
https://firesecurityproducts.com/en/content/intrusi
on-intro
Thermal
Diamond
Drilling
lance
disk
1
5
5
1
5
5
3
3
4
4
4
4
2
2
or scan the QR code.
3 / 12

Publicidad

loading

Este manual también es adecuado para:

Plus vvs300Plus vvs320