Adjusting the dosage of the system
care Advance RM 110/RM 111
Determining the hardness of tap water:
through the public water supply works,
–
using a hardness tester (order no.
–
6.768-004)
Water hard-
Scale on the system care
ness (°dH)
service switch
<3
OFF (no dosing)
3...7
1
7...14
2
14...21
3
>21
4
Set the service switch according to the
water hardness in the table.
Note: Observe the following when using
system care Advance 2 RM 111:
Calcification protection: See table
–
Pump care: Set the service switch to at
–
least setting 3.
Refill detergent
Caution
Risk of injury!
Use Kärcher products only.
–
Under no circumstances fill solvents
–
(petrol, aceton, diluting agent etc.)
Avoid eye and skin contact.
–
Observe safety and handling instruc-
–
tions by the detergent manufacturer.
Kärcher offers an individual cleaning
and care appliances program.
Your dealer will consult you gladly.
Refill detergent.
Install the hand-spray gun, the jet
pipe, the nozzle and the high pres-
sure hose
Figure 4
Connect ray tube with hand spray gun
Tighten the screw connection of the
spray lance fingertight.
Insert high pressure nozzle into cover-
ing nut
22
Install covering nut and tighten firmly
Connect the high pressure hose to the
high pressure connection point of the
machine.
Installing spare high pressure hose
Figure 5
Water connection
For connection values refer to technical
specifications
Attach supply hose (minimum length
7.5 m, minimum diameter 3/4") to the
water supply set by means of a hose
clamp.
Connect the supply hose to the water
connection point of the machine and at
the water supply point (for e.g. a tap).
Note: The supply hose and the hose clamp
are not included in the scope of delivery.
Power connection
For connection values, see technical
–
data and type plate.
The electrical connections must be
–
done by an electrician according to IEC
60364-1.
The voltage indicated on the type plate
–
must correspond to the voltage of the
electrical source.
The installation of the electrical plug
–
may only be performed by the author-
ised customer service/electrician. The
electrical plug is not included.
Danger
Danger of injury by electric shock.
Unsuitable extension cables can be
–
hazardous. Only use extension cables
outdoors which have been approved for
this purpose and labelled with a suffi-
cient cable cross section:
Always unwind extension lines com-
–
pletely.
The plug and coupling of the extension
–
cable used must be watertight.
– 4
EN