Descargar Imprimir esta página

Sullair SRL Serie Manual De Uso página 25

Ocultar thumbs Ver también para SRL Serie:

Publicidad

Technical data / Caractéristiques techniques / Datos técnicos
Electrical
Compressor
supply inlet
1
MC1 (Ac/Wc)
RLA
(A)
SRL- - 1200
460/3/60
10
SRL- - 1400
460/3/60
10
SRL- - 1600
460/3/60
10
SRL- - 2000
460/3/60
12.8
SRL- - 2400
460/3/60
15.1
SRL- - 3000
460/3/60
19.7
SRL- - 3800
460/3/60
24.1
SRL- - 5000
460/3/60
31.1
SRL- - 6000
460/3/60
39
Calibration values
Hot gas valve
62.4 --- 66.7 PSIg
SRL- - 1200 --- SRL- - 6000
4.3 --- 4.6 barg
Fan motor
3
EV1 (Ac)
LRA
RLA
RLA
(HP)
(HP)
(A)
(A)
(A)
63
1.25
1.07
63
1.25
1.07
75
1.25
1.07
1.25
99
1.9
1.54
1.9
125
1.9
1.54
1.9
158
1.9
1.54
1.9
187
1.9
1.54
1.9
225
1.9
1.54
1.9
272
1.9
1.54
1.9
Fan pressure switch
9
HGV
12 PV
ON: 261 PSIg
OFF: 203 PSIg
ON: 18 barg
OFF: 14 barg
Fan motor
Fan motor
3
EV2 (Ac)
3
EV3 (Ac)
RLA
(HP)
(HP)
(HP)
(HP)
(A)
---
---
---
---
---
---
---
---
1.07
---
---
1.54
---
---
1.54
---
---
1.54
---
---
1.54
---
---
1.54
1.9
1.54
1.54
1.9
1.54
High pressure switch
15 HP
406 PSIg
28 barg
Minimum
Maximum
circuit ampacity
protection device rating
MCA (Ac)
MCA (Wc)
HACR (Ac)
(A)
(A)
(A)
(A)
(A)
(A)
13.8
12.5
15
13.8
12.5
15
15.0
12.5
20
19.8
16.0
20
22.7
18.9
30
28.4
24.6
30
33.9
30.1
40
44.6
38.9
60
54.5
48.8
60
Low pressure switch
6
LP
21.8 --- 36.3 PSIg
1.5 --- 2.5 barg
SRL- - 1200 --- SRL- - 6000 (60Hz)
Minimum section
validated cable for
validated cable for
eletrical connection
HACR (Wc)
(A)
(A)
15
12AWG
15
12AWG
15
12AWG
20
8AWG
20
8AWG
30
8AWG
40
8AWG
40
6AWG
60
6AWG
Water pressostatic valve
22 WPV
232 PSIg
16 barg
23