Filter Maintenance- the TR700 is equipped with a 100-mesh screen filter. This filter should be
checked periodically. A partially clogged filter will slow down the recovery rate of this unit.
Check the filter cartridge as follows:
• Use a 5/8" socket or boxed end wrench to loosen the suction port as shown in Figure 1.
• Once loose, remove the suction port- filter cartridge as shown in Figure 2.
• Either clean the current cartridge or replace with new cartridge.
• Inspect O-ring. Re-lubricate with compressor oil or equivalent.
• Place filter cartridge back into suction port fitting.
• Hand tighten this assembly back onto the TR700 unit.
• Use a 5/8" socket or boxed end wrench to tighten 1/8 of a turn.
Do not over tighten, damage to the O-ring may occur.
• Check the connection for leaks.
Figure 1
CPS Products, Inc. guarantees that all products are free of manufacturing and material defects to
the original owner for three years from the date of purchase. If the equipment should fail during
the guarantee period it will be repaired or replaced (at our option) at no charge. This guarantee
does not apply to equipment that has been altered, misused or solely in need of field service
maintenance. All repaired equipment will carry an independent 90 day warranty. This repair
policy does not include equipment that is determined to be beyond economical repair.