Fault/problem
The LED control lamp
is flashing red and the
alarm is sounding
There is no display on
the LED control lamp
Power leakage or
short-circuit of fence
connection
Poor grounding
Voltage loss/leakage
from the fence
Fence voltage
insufficient
Grounding voltage is
not displayed
Error E1
60
Solution
∙
The battery voltage has fallen below 11.6 V. Replace the battery
with one that is sufficiently charged, or connect the device to the
230 V mains supply.
∙
Check whether the fence was suddenly placed under strain (fallen
branches, trapped animal, etc.) or the voltage was reduced. Correct
the cause.
The energiser was switched off manually, or the battery voltage has
fallen below 11.4 V and the fence was switched off automatically. This
is done to protect the battery from deep discharge (which destroys
the battery). Replace the battery with one that is sufficiently charged,
or connect the device to the 230 V mains supply.
Info
Until the battery voltage reaches at least 12 V, the red LED
stays lit.
Do not use any conventional cables for the fence connection. We
recommend the use of a high voltage cable (Item no. 32611).
∙
Follow the tips given in Section 7.3.
∙
Check whether the grounding rod is corroded. Replace corroded
grounding rods.
∙
Check whether the cables/connections are intact. Replace defective
parts.
∙
Remove vegetation from the fence (by mowing or pruning).
∙
Check whether the insulators are defective (recognisable by
"clicking" and, possibly, sparking of insulators). Replace defective
and weather-worn insulators.
∙
Check whether the conductor material is touching the ground (e.g.
as a result of breakage, insufficient mechanical tension). Repair
the fencing. Use only special connection pieces and tighten the
conductor material.
∙
Check whether the conductor material possesses any undesirable
properties (thin conductor, high resistance). Use high-quality
conductor material with a low resistance and large diameter. Ensure
that the conductor material has high-quality wiring.
∙
Make sure that the conductor material is not connected using tied
knots, and that the connection is adequate. Use suitable special
connection pieces for the conductor material.
Fence too long. Reduce the area or use a more powerful energiser.
No grounding post connected to the green connector to check the
grounding voltage and/or fence resistance is > 500 ohms (see Section
7.4.3).
Fault in measurement of output voltage The fence system is not
working properly. The output of the energiser is limited to 5 J and
the measurement of the grounding is not being carried out. Contact
our Service department.
INSTRUCTION MANUAL VOSS.FARMING XTREME DUO RF
41550 - 11.2021 - V2