5
CHECK CONNECTIONS FOR LEAKS.
Move HANDLE down into "off" position.
Turn on water supplies and check connections for leaks
Operate HANDLE (2) up and down, left and right to flush
water lines thoroughly.
Operate HAND SPRAY and check connections for leaks.
6
SERVICE
If faucet drips, operate HANDLE several times from "off" to "on." Do not
apply excessive force.
FLOW CONTROL DEVICE may accumulate dirt. To remove the FLOW CONTROL DEVICE,
unthread SPRAY AND HOSE ASSEMBLY and rinse clean FLOW CONTROL DEVICE.
Clogged CARTRIDGE outlets or inlets may cause reduced flow.
To clean, first turn off water supply then:
Remove INDEX BUTTON (1), loosen HANDLE SCREW (2) and remove HANDLE (3).
Unthread the ESCUTCHEON CAP (4). Unthread three MOUNTING SCREWS (5).
Lift CARTRIDGE (6) off MANIFOLD (7) and remove CARTRIDGE SEALS (8).
Clean MANIFOLD (7), CARTRIDGE (6) ports and SEALS (8).
Place SEALS (8) into CARTRIDGE PORTS (6A).
Place CARTRIDGE (6) onto MANIFOLD (7) and tighten MOUNTING
SCREWS (5) alternately.
Replace ESCUTCHEON CAP (4), HANDLE (3), tighten HANDLE
SCREW (1) and install INDEX BUTTON (2).
HOT LIMIT SAFETY STOP ADJUSTMENT
By restricting handle rotation and limiting the amount of hot water allowed
to mix with the cold, the HOT LIMIT SAFETY STOP reduces risk of accidental
scalding. To set the maximum hot water temperature of your faucets, all you
need to do is adjust the setting on the HOT LIMIT SAFETY STOP.
Remove HANDLE BUTTON (1) and loosen SET SCREW (2). Pull
HANDLE (3) off valve stem. Pull off CAP (4). Use a flat blade
screwdriver or your fingers to pull up and rotate red HOT LIMIT
SAFETY STOP (5). Follow Step "A" or "B" to adjust min./max.
discharge temperature. "0" being the hottest to "7" the coldest
temperature setting. Factory set at "0".
Replace ESCUTCHEON CAP (4), HANDLE (3), tighten
HANDLE SCREW (1) and install INDEX BUTTON (2).
7
CARE:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
.
"RED RING"- HOT LIMIT SAFETY STOP
"B"
ADJUSTMENT WHEN
WATER IS TOO COLD
PRY RED RING UPWARD
AND ROTATE
COUNTER-CLOCKWISE
CHECK CONNECTIONS
FOR LEAKS
SPRAY AND HOSE
ASSEMBLY
ADJUSTMENT WHEN WATER IS TOO HOT
PRY RED RING UPWARD
AND ROTATE CLOCKWISE
"A"
TEMPERATURE
SETTING NUMBERS
"B"
2
1
6A
FLOW CONTROL
DEVISE
"A"
M965774 Rev. 1.2 (4/21)
3
4
5
6
8
7