Anexo
7.2.2
BWL-1S(B)-05/07 / 230 V (2017 - ...)
RED
BROWN
BLUE
C(W)
R(U)
S(V)
COMPRESSOR
DC_LED
WHITE
BLUE
Fig. 7.3
BWL-1S(B)-05/07 / 230 V (2017 - ...) Esquema de conexionado
9147377_202007
M
M
HMI
GND
COMPRESSOR
LED
U
SELF TEST
V
J1
W
MAIN EEV
FLASH
OMT
PORT
OAT
CTT
OCT
DIP SWITCH
HST
GND
BH/CCH 250V/1A
M
RV
FUSE
T3.5AH 250V
BLUE
POWER
BROWN
SUPPLY
DANGER!!
HIGH DC VOLTAGE!!
DO NOT TOUCH WHILE LED'S
ARE ON AND 1 MINUTE AFTER
POWER OFF
POWER SUPPLY(BY INSTALLER):
C - 1PH/230VAC / 50Hz
3x 2.5mm²
CABLE BETWEEN INDOOR AND
OUTDOOR UNITS:
A - 3x 1.5mm² (OPTIONAL)
B - 2x 0.75mm²
LEGEND:
BH - BASE HEATER
CCH - CRANK CASE HEATER
COMM - COMMUNICATIONS
CTT - COMPRESSOR TEMPERATURE
EEV - ELECTRONIC EXPANSION VALVE
GND - GROUND (EARTH)
HPS - HIGH PRESSURE SWITCH
HST - DRIVER TEMPERATURE
LPS - LOW PRESSURE SWITCH
M2L - AUXILARY COMMUNICATION
MDC - MULTI DC SUPPLY
OAT - OUTDOOR AIR TEMPERATURE
OCT - OUTDOOR COIL TEMPERATURE
OMT - OUTDOOR COIL MIDDLE TEMPERATURE
RV - REVERSE VALVE
SB - STAND-BY
------ - OPTIONAL
WHITE
C1
B
BLACK
C2
BROWN
L
C
BLUE
N
GND
YEL/GRN
GND
GND
BROWN
A
L
BLUE
N
N
L
LINE
FILTER
N-IDU L-IDU
N
L
OUTDOOR UNIT WIRING DIAGRAM
ODUC 3-4 HP
P/N: 414934 Rev 03
COMMUNICATION
TO INDOOR UNIT
POWER SUPPLY
TO OUTDOOR UNIT
POWER SUPPLY
TO INDOOR UNIT
(OPTIONAL)
WOLF GmbH | 49