DEHUMIDIFIER INSTALLATION

6
1. The Santa Fe UltraMD33 can be installed in a variety of applications:
2x6 16" O.C. Stud Wall Installation
2x4 16" O.C. Stud Wall Installation
- If penetrating both walls and the opposite side is a mechanical room, no additional accessories are needed.
- If back wall is functional space, installation requires 2x4 Wall Mount Bezel Kit (PN 4037767).
- If the other side of the wall goes into an unconditioned space, it may require the 2x4 Rear Panel Kit (PN 4037768)
to add a layer of insulation to prevent condensation.
Surface Mount Installation
- Surface Mount Kit (PN 4037766) required for installation.
Surface Mount, Bezel Kit and Rear Panel installations can be viewed at
https://www.santa-fe-products.com/product-category/accessories/
Items Included in Box:
Santa Fe UltraMD33 Dehumidifier
Diffuser Cover with Filter
Santa Fe UltraMD33 Installation Instructions
Drain Hose (10')
Power Cord (10')
Hose Clamp
Grommet for Drain Hose
Non-Metallic Cable Clamp
Bag A: #10 Wood Screws (5)
Bag B: #8 Sheet Metal Screws (5)
Bag C: Tamper Resistant Screws for
Diffuser Cover (5) and 1/4" Hex T-15 Torx
Security Bit
Bag D: Phillips Screws for Diffuser Cover (5)
WARNING!
SHUT OFF BREAKER / POWER BEFORE BEGINNING INSTALLATION.
AVERTISSEMENT!
FERMEZ LE DISJONCTEUR/ALIMENTATION AVANT DE COMMENCER L'INSTALLATION.
Step 1. Remove the shipping bracket by carefully cutting
the two zip ties with side cutters or shears. Remove the
four screws from the shipping bracket using a 1/4" hex
nut screwdriver.
Step 2. Remove electrical box cover from the unit by
removing the two screws on the cover using a 1/4" hex
nut screwdriver.
800.533.7533 | Santa-Fe-Products.com

Tools Required:

Phillips Screwdriver
1/4" Hex Nut Screwdriver
Level
Square or Ruler
Stud Finder
Wire Stripper
Drywall Saw
Side Cutters or Carpenters
Knife
Tape Measure
Pen or Pencil
1.
Shipping
Bracket
2.
Electrical
Box
Santa Fe ULTRAMD33 Installation & Operation Instructions
Other Materials To Consider:
Electrical wire (depends on
installation and distance of
wiring requirements)
Additional hose length or PVC
pipe (depends on drain location)
Materials to repair drywall
(depends on installation)
Condensate Pump Kit
(depends on drain location)
GFCI Outlet (if using supplied
power cord)
7