NOTE: The only time the selected charge rate does not display at the full selected rate is when
the battery is nearly full and charging at either step two or three. The display will be showing a
slowing charge rate. To return to 2A, press the 2/10/25 amp button. When the battery is fully
charged, the Charging Complete LED is lit and "FUL" is displayed on the digital display.

CHARGING THE BATTERY

1. Charger displays circulating pattern when battery and AC power are connected prop-
erly. Select battery type and press 2/10/25 amp button to begin charging at 2 amps
rate; the charger sounds a beep and displays charging current.
WARNING: If charger displays F02, and lights FAULT indicator, the connection to
battery terminals is bad. Clean battery terminals, then reconnect clamps.
If the charger displays an F06, or the charger displays an F06, the red
(positive) and black (negative) clamps are incorrectly connected to battery
terminals. Reverse the clamps.
NOTE: The charger starts charging at 2 amps rate automatically if 2/10/25 amp button
is not pressed within 3 minutes after applying AC power. The Battery Type Selector
will automatically default to "gel".
NOTE: If the display on the charger varies between F03 and amp rate, the battery is sulfated
and the charger is trying to give it some charge. Please run the desulfation process.
• Charger occasionally sounds a beep and displays 0.0 during self-test or charg
ing stage changes.
2. Pressing the 2/10/25 amp button again advances charging rate to 10 amps and
pressing once more advances charging rate to 25 amps.
NOTE: • If the battery is near full, it will fall back to lower charge rate.
• Pressing the 2/10/25 amp 4 times advances to standby mode; sounds a
beep, displays 000 and stops charging.
3. The battery charger displays the charge current. To view the battery voltage, press BAT-
TERY VOLTAGE button. The charger will sound a beep and display the battery voltage
for 5 seconds, then returns to display charge current.
4. The display shows FUL when the battery is fully charged.
5. Disconnect the AC power cord first, then the NEGATIVE clamp and finally the POSITIVE
clamp.
AUTOMATIC FLOAT CHARGING – Ideal for Maintaining a Fully Charged Battery
1. Keep the AC power and battery connected after battery is fully charged.
2. The charger monitors the battery and tops it off as needed.
3. The display shows the current in amps and turns on the Float Charge indicator and
displays FUL when completed.
4. To view battery voltage, press BATTERY VOLTAGE button.
NOTE: • After AC power interruption, charging restarts at 2 amps rate automatically.
The Battery Type Selector will automatically default to "gel."
EQUALIZING: the process by which the fluid in each of a battery's cells is equalized.
This process occurs after charging is complete.
WARNING – NEVER TRY TO EQUALIZE A GEL CELL, THE RESULTING EXPLOSION COULD
CAUSE SERIOUS INJURY, DEATH AND PROPERTY DAMAGE.
WARNING – TURN OFF ALL VOLTAGE SENSITIVE DEVICES DURING THE EQUALIZATION
PROCESS. The frequency which the equalization process needs to be run depends on
the use of the battery. The more use the battery receives, the more undercharged it is,
the more times the battery should be equalized.
1. Do not use this mode on sealed or valve regulated batteries. This mode is only meant
for wet (unsealed/vented) batteries.
2. Make sure there are no flammable sources near the recharging sight.