GND VT
-
Electrical connections as per NFC15-100 standard
1
2
3
4
This connection must be made by a qualified and trained technician. To make the connection, the
transmitter MUST NOT BE ENERGIZED.
For TM110 – AO and TM110 – AN models with
0-10 V output – active, 4 wires:
-
+
GND VT
GND VT
V
-
-
+
+
Display/regulator/PLC
1
1
2
2
3
3
4
4
5
passive type
-
-
+
+
V
V
4 wires
Display/regulator/PLC
Display/regulator/PLC
passive type
passive type
1
2
4 wires
4 wires
Power supply 16-30 Vdc
+
+
Vdc
-
IT
1
1
2
2
2'
2'
2 wires
Settings and use of the transmitter
Power supply 16-30 Vdc
Power supply 16-30 Vdc
+
+
+
+
Vdc
Vdc
Configuration
-
-
IT
IT
+
+
CAUTION: the transmitter MUST NOT BE ENERGIZED
GND VT
before a configuration. Then, proceed to the
2 ls
2 ls
-
+
required settings, with the DIP switches (as shown
1
2
3
4
5
on the drawings hereafter). Once the transmitter
configured, it can be powered up.
To configure the transmitter, unscrew the 4 screws of the casing
then open it.
The switches allowing the different settings are accessible.
-
+
V
automate type passif
+
-
+
5
6
7
4 wires
-
+
-
-
+
+
Power supply
5
6
6
7
7
24 Vdc
or
4 wires
4 wires
N L
6 7
N
L
-
-
+
+
Power supply 24 Vac
Power supply
Power supply
Classe II
24 Vdc
24 Vdc
or
or
N L
N L
6 7
6 7
N
N
L
L
2'
Power supply 24 Vac
Power supply 24 Vac
Classe II
Classe II
For TM110 – PO and TM110 – PN models
with 4-20 mA output – passive:
-
Display / regulator /
A
PLC passive type
+
-
-
Display / regulator /
Display / regulator /
A
A
or
PLC passive type
PLC passive type
-
+
6
7
-
+
Alimentation
24 Vdc
ou
GND VT
-
+
1
2
3
4
5
To make a 3-wire connection, BEFORE POWERING
UP THE TRANSMITTER please connect the output
-
+
ground to the input ground. See drawing below.
V
GND VT
GND VT
-
-
+
+
Display/regulator/PLC
1
1
2
2
3
3
4
4
5
passive type
-
-
+
+
V
V
3 wires
Display/regulator/PLC
Display/regulator/PLC
passive type
passive type
3 wires
3 wires
+
+
Vdc
or
-
IT
-
2 wires
+
+
+
Vdc
Vdc
or
-
-
IT
IT
-
GND VT
1
2 wires
2 wires
-
+
-
2
1
2
3
4
5
6
3
4
Off
-
+
V
automate type passif
-
+
6
7
3 wires
+
Power supply 24 Vdc
-
-
-
+
+
5
6
6
7
7
or
GND VT
3 wires
3 wires
N
L
-
+
4 5 6
7
+
+
Power supply 24 Vdc
Power supply 24 Vdc
N
L
-
-
Power supply 24 Vac
Classe II
or
or
GND VT
GND VT
-
-
+
+
N
N
L
L
4 5 6
4 5 6
7
7
N
N
L
Power supply 24 Vac
Power supply 24 Vac
Classe II
Classe II
Display/regulator/PLC
active type
A
16-30 Vdc
2 wires
Display/regulator/PLC
Display/regulator/PLC
active type
active type
+
A
A
16-30 Vdc
16-30 Vdc
On-off switch
-
+
Measuring range
7
setting
2 wires
2 wires
Unit of measurement
setting
On
+
Alimentation 24 Vdc
-
ou
GND VT
L