WARNING
Fire hazard. Wiring must comply with
!
applicable electrical standards and include
a properly sized fuse or circuit breaker.
Improper wiring can cause a fire resulting in
injury or death.
IF YOU ARE NOT FAMILIAR WITH APPLICABLE
CAUTION
ELECTRICAL STANDARDS, HAVE THE UNIT INSTALLED BY A
QUALIFIED ELECTRICIAN.
Figure 5.
Red (+)
Fuse
CAUTION
Suggested wiring information is given as a reference. For proper
information, please reference ABYC E-11, AC and DC Electrical
Systems on Boats guidelines.
Wire Size
Table
Total Wire Length - feet (meters)
Pump
0 - 20 ft
20 - 35 ft
Voltage
(0 - 6 m)
(6 - 9 m)
12 VDC
#14 AWG
#12 AWG
(2.5 mm
)
(4 mm
2
24 VDC
#16 AWG
#14 AWG
(1.5 mm
)
(2.5 mm
2
CAUTION
Motor case could get hot during extended
operation. Prolonged contact with skin may cause a burn.
CAUTION
Install a Pumpgard
TM
location (for inspection and cleaning) between the tank and
pump inlet in order to protect valves from debris.
Operation
• Fill water tank
• Open all faucets
• Turn pump switch "ON"
Figure 6.
Initial Start Up
Demand Off
Demand On
• When water is free of air, turn all faucets off beginning with
the faucet closest to the pump (Figure 6)
Important: Do not operate the pump more than 15 minutes
continuously.
Black (-)
Switch
Battery
35 - 55 ft
(9 - 12 m)
#10 AWG
)
(6 mm
)
2
2
#12 AWG
)
(4 mm)
2
strainer in an accessible