English
Introduction
This document is intended for experienced engineers
who are familiar with PAC products and health and safety
considerations.
Additional information on software installation and
operation is given in the documentation and help files
provided with the administration software.
All similar controllers on the system should have
the same firmware version number.
A firmware download to the new controller may be
required, see the help file for further details.
Tamper and Override Terminal (NC)
Before powering up, use a short piece of cable to link:
tamper (TAMP) and 0V terminals.
l
override (OVERRIDE) and 0V terminals.
l
Override can be configured for EOL operation if required.
RS-485 Connection
When shielded cables are used, connect the shield on
one controller to the earth terminal labelled "SHIELD".
Only the first and last controllers in the chain, must
have the RS-485 dipswitch set to "IN".
RS-485 LED
RED
The controller is transmitting data
Another controller is transmitting data on
GREEN
the network
Lock EMF Suppression
All locks must be fitted with a means of suppressing back
EMF ('spikes'), which are generated by most electric
releases, especially magnetic locks.
All readers and controllers supplied by PAC are supplied
with a Metal Oxide Varistor (MOV).
For currents >1A use the large MOV supplied with the
controller.
For currents <1A use the small MOV supplied with the
reader.
The MOV will prevent the controller from suffering long
term damage.
Whenever possible this device should be fitted across the
lock terminals. If for any reason the lock terminals are
inaccessible, the MOV may be fitted across the lock
output.
The lock relays are protected by a 3A circuit breaker in
line with the RELAY COM connection. These will
automatically be reset when the overload has been
removed; both lock outputs are independent.
Description
– Page 4 of 20 –
Legend for Wiring Diagram on page 3
1
RS-485 connection
2
Dipswitch settings
1.
RS-485 termination (IN or OUT, default =
OUT)
2.
Reader voltage selector (12/24V or 5V,
default = 12/24V)
3
RS485 status LEDs
4
RS-232 status LEDs
5
Door 1 LEDs
6
Reader
SIGA/SIGB
0V (sounder)
0V (tamper/DC - door
7
Request to Exit (NO)
8
Door Contact
9
Lock wiring options
FAIL SAFE—connect to NC
l
FAIL SECURE—connect to NO
l
10
Door 2 LEDs
11
Serial Number and Barcode
12
One-Touch™ button
13
System status LED
14
Power Access
15
Battery Backup
16
12V/24V PSU
(Battery) +
(Battery) -
17
PC RS-232 or Ethernet connection
18
Cover Tamper Switch (NC)
19
Door Override (NC)
Removal of short will operate lock relay
l
NOT rated for use as a FIRE OVERRIDE
l
20
Wiegand Reader
+V
Red
Brown
LED
White
0V
Black
Yellow
Blue
contact)
RTE
Blue
0V
Black
PAC Wiring ONLY
VIN
Orange
0V
White
MSTAT
Pink
Red
Black
EARTH
Green/Yellow