Pin Assignment


3
4
5
Important operating and connection instructions
• Voltage for control inputs: 5 ~ 4V (+0%), Ri = 3.9kOhm
• Max. current of open-collector outlet: 5mA, max. voltage = 4V
• Please use only the original cable (included in delivery).
• Connection may only be carried out by authorized personnel.
• The plug-socket combination (control and power supply) at #7735 is only
watertight when plug is fully inserted (IP66).
3.3 Configuration of the 4 pin power socket
Colour
Function
white
Common ground (GND) for switch inputs  and 3
brown
Switch input, switcher external/internal
green
Switch input, external ON/OFF
yellow
Switch input + (control output for external device)
grey
Switch input – (control output for external device)
Pin Assignment
Colour

blue

brown
3
4
yellow/green
5
Function
Zero
Phase
Not connected
Ground