Electrical connection

All installation must be carried out by a qualified electrician. Before connecting the mains supply ensure that
the mains voltage corresponds to the voltage on the rating plate.

Direct Connection

The appliance must be connected directly to the mains using an omnipolar circuit breaker with a minimum
opening of 3 mm between the contacts. The installer must ensure that the correct electrical connection
has been made and that it complies with the wiring diagram. The cable must not be bent or compressed.
Regularly check the power cord for damage. If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons in order to avoid a safety hazard.
WARNING: THIS IS A CLASS I APPLIANCE AND MUST BE EARTHED.
This appliance is supplied with a 3 core mains cable coloured as follows:
Brown = L or Live
Blue = N or Neutral
Green and Yellow = E or Earth
This appliance should be connected directly to the consumer unit with a 3 Amp Residual Current
Device (RCD) protecting its circuit.
To avoid the risks that are always present when you use an electrical appliance it is important that this
appliance is installed correctly and that you read the safety instructions carefully to avoid misuse and
hazards. Please keep this instruction booklet for future reference and pass it on to any future owners.
After unpacking the appliance please check that it is not damaged. If in doubt, do not use the appliance but
contact Customer Services.
The manufacturer declines all liability for damage caused to persons and objects due to incorrect or
improper installation of the appliance. Any permanent electrical installation must comply with the latest
wiring regulations applicable to your country and for your own safety a qualified electrician or contractor
must undertake the electrical installation.

Technical Data

Gas on glass 4 burner hob 60cm
Supply voltage:
Total heat input (Natural gas):
Total heat input (LPG):
Electric power
External dimensions (W x H x D):
Net Weight:
Injector Table
Gas Category
UK & IE: II2H3+ (G20 20 mbar, G30 28-30 mbar, G31 37 mbar)
FR: II2E+3+ (G20 20 mbar, G25 25 mbar, G30 28-30 mbar, G31 37 mbar)
ES & PT: II2H3+ (G20 20 mbar, G30 28-30 mbar, G31 37 mbar)
RO: II2H3B/P (G20 20 mbar, G30 30 mbar, G31 30 mbar)
PL: II2ELs3B/P (G20 20 mbar, G2.350 13 mbar, G30 37 mbar, G31 37 mbar)
5059340445793_MNL_IN_V03.indb 10
5059340445793_MNL_IN_V03.indb 10
220-240 V~ 50 Hz
7.5 kW
7.5 kW (545 g/h)
5.2W
590 x 72 x 510 mm
14.4 kg
10