Descargar Imprimir esta página

Weka FU6 D/C Instrucciones De Servicio página 17

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 32
Status display changes its status automatically. Fault signals will be deleted when the machine is restarted (if
the cause of defect has been removed).
As soon as the converter is connected to the power supply the Bluetooth interface will be activated for six
minutes. Within this time frame updates can be executed. If there is no access within this time frame the interface
will be deactivated and there is no connection possible as long the converter stays connected to the power
supply. Once the converter gets disconnected from the power supply for two minutes and is reconnected a new
time frame of six minutes will be opened to execute an update.
In the following, the individual steps for carrying out an update are described in detail:
1) Connect the converter to the power supply. The status and error report LED on the side of the case will
start flashing or light permanently if there is a machine connected. The converter is ready and the
Bluetooth interface is activated. If the LED stays off please check the power supply and the wiring.
Furthermore pay attention to the additional information below.
2) Run the "WEKA Service App" on the smartphone (see additional information below) and select "CHECK
FOR UPDATES". Searching can take up to 30 seconds, during this time a list of all available converters
will be created showing the converters by their internal serial number, e.g. "WEKA FU6 D/C Sn.:00000".
3) After selecting a listed converter the "WEKA Service App" will compare the current firmware version to
the available versions on the WEKA server and will prompt if an update is available.
If an update is available please confirm by selecting "Yes" to start the process. The converter will
perform all necessary steps fully automatically, meanwhile you can observe the data transmission on
the "WEKA Service App". Once data transmission is completed please wait
the status and error report will start flashing again. The converter has now booted up with the new
firmware and is ready for use.
4) In case you did cancel the update or a data transmission error occurred or there is no update available
the converter will restart automatically after one minute and will boot up with the current firmware again.
The update process can be executed at any time again with the instructions above.
G U A R A N T E E
We provide 12 months warranty for the WEKA Frequency converter from the date of delivery. During this period
we will rectify material and production defects free of charge. This warranty does not cover normal wear,
overloading, non-compliance with the operating instructions and intervention by unauthorized persons or the
use of parts from other companies.
R E C Y C L I N G
According to the European regulation 2002/96/EG we have to take back old machines for departing
them by substance and for recycling (see sign on name plate). Please make sure that the old tool
does not get into the unsorted municipal solid waste, but that they are given back to us, resp.
abroad to our distributors.
Original instructions - Subject to change without notice 0720
16
until the green LED of

Publicidad

loading

Productos relacionados para Weka FU6 D/C