Bionaire BD15 Manual De Instrucciones página 4

Electrónico silencioso
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

OPERATING
INSTRUCTIONS
TURNING UNIT ON AND OFF
1. Plug unit into an appropriate electrical outlet. All
lights will go on and after 1 second go out. The
unit will beep 3 times.
2. Press the Power button
power light
will go on. The unit will beep
one time and go to the Continuous Dehumidifying
mode
.
3. To turn the unit off, press the Power button again.
CONTINUOUS DEHUMIDIFYING
To set the unit to operate continuously, turn the unit
on or press the Mode button
dehumidifying light
The unit will operate in high speed, at 60% RH.
NOTE: If you adjust the Humidity Control button
during the continuous dehumidifying mode, the unit
will go to the automatic dehumidifying mode.
AUTOMATIC DEHUMIDFYING
1. The unit has an automatic dehumidifying and a
quiet automatic dehumidifying function. Press the
Mode button
until the automatic dehumidifying
light
or quiet automatic dehumidifying light
goes on.
2. In automatic dehumidifying mode, the unit will
monitor the relative humidity of the environment
and adjust its functionality accordingly, cycling on
and off to maintain your desired comfort level.
3. In quiet automatic dehumidifying mode, the unit
will operate as in the automatic dehumidifying
mode but at low speed.
4. The default humidity level is set at 60% relative
humidity (RH). Press the Humidity Control button
until you reach your desired humidity level.
Please refer to the humidity control instructions
below for additional operating instructions.
USING THE TIMER
Once the unit is powered on and an operating mode
is selected, press the Timer button
or 8 hours. To turn timer off, press Timer button until
all timer lights go out.
BD15-LA_15ESM1.indd 4
to start the unit. The
until the continuous
goes on.
, choosing 2, 4
English -4
HUMIDITY CONTROL
When the unit starts, the humidity level of the
environment will be shown on the display.
1. For automatic dehumidifying or quiet automatic
dehumidifying modes, press the Humidity Control
button to select the desired humidity level. The
control allows you to adjust level in 5% intervals
from 40% to 80%.
2. If the unit humidity level sensor detects humidity
levels in the environment that are lower than
the selected humidity level, the compressor will
shut off and the fan will work on low speed. The
humidity level of the environment must be higher
than the humidity level selected in order for the
unit to start operating again.
AUTOMATIC DEFROSTING
If the room temperature drops down to 16ºC or
lower, the unit's temperature sensor will set the
compressor to dehumidify for 25 minutes and then
shut off automatically. The fan will keep running for 7
minutes to defrost in a cycle.
NOTE: When the defrost light
display, the compressor will shut off and the fan will
run at high speed.
WATER FULL PROTECTION
& AUTO-SHUTOFF
When the water reservoir is full, the unit will sound
an alarm beeping 10 times (for about 5 seconds).
The water reservoir full light
on the screen and the unit will shut off automatically.
This indicates that it is time to empty the water
reservoir before using the unit again. Once the empty
water reservoir is placed back into the unit, it will
take up to 3 minutes for the dehumidifier compressor
to work again. This is a protection feature. If you
wish to restart the unit without waiting, unplug it from
the electrical outlet and plug it in again.
WATER DRIP PROTECTION
When the water reservoir is removed for emptying,
this device will keep the condensed water that
continues to drip. Once the water reservoir is placed
back in the unit, it will release this water into the
reservoir.
is shown on the
will be displayed
3/6/15 10:18 AM