1. Disconnect the building-side connecting
cable from the power supply and secure it
against being switched on again. To do
this, trip the corresponding circuit breaker
of the house installation.
2. Loosen the 4 screws (1) on the back of
the socket column, remove the stainless
steel plate (2) and then the plastic plate
(3).
3. Loosen the cable sleeve (4) and guide
the building-side connection cable into the
socket box (5).
4. Connect the building-side connection
cable to the luster terminal inside the
socket box (5) as shown in Figure 2.
5. Fix the connection cable by tightening
the cable sleeve (4) again and close the
socket box (5). Replace the stainless steel
plate (2) and hand-tighten the screws (1).
6. Turn the power back on. The installation
is completed.
Subject to technical changes
LEDs Com GmbH, Dohrweg 2a, D-41066 Mönchengladbach, www.leds-com.de, Tel. +49 (0) 2161 - 5 75 99 76
English
Figure 1
1: Screws
2: Stainless steel plate
3: Plastic plate
Figure 2
Socket column (LC-SS-9188) - Assembly instructions
4: Cable sleeve
5: Socket box
11/2022