Descargar Imprimir esta página

CAN SL Serie Manual De Instrucciones página 119

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

If connecting the quick joint is hard or impossible, immediately stop the operation and contact the
manufacturer of the outdoor gas valve. Do not force or try to alter the connection fitting in any way.
To connect the product to the gas system follow the procedure below:
step
1
Take the free end of the gas cylinder connection hose, making sure that the cylinder is stable and properly
positioned on the ground.
2
Connect this end to the connection terminal on the appliance. The terminal differs depending on the product
installation country.
3
After connection, turn the gas supply valve on the cylinder.
If a pressure gauge is available, always check that the gas supply conditions are compatible with the pressure
regulator supplied.
Before operating the appliance, perform a leak test on the connections with an aqueous soap solution. In the
event of leakage, immediately stop the gas flow, remove any residual gas from the connection hose and make
a new connection.
Avoid any type of mechanical stress on flexible hoses during installation and use (protection against
traction, twisting, crushing, etc.).
ATTENTION!
Perform maintenance and periodically replace the flexible hose within the expiration date
written on the sheath. Do not use expired or damaged flexible hoses by any means.
ATTENTION!
During installation, connection and use, the flexible hose of the appliance must not be twisted,
pulled or subjected to any other mechanical/thermal stress which may jeopardise its tightness
and resistance.
ATTENTION!
Using naked flames to check tightness and put the device into service is strictly not allowed!
action
Installation, use and maintenance instruction manual
Ed. 11/2019 Rev. 00
47

Publicidad