1. SPECIFICATIONS

1.1 Technical specifications

Parameter
Minimum - Maximum draught
Fuel consumption
Smoke mass flow rate
Performance
Nominal output
Power range
Average CO concentration at 13% of O
Average NO
concentration at 13% of O
x
Average OGC concentration at 13% of O
Particle concentration at 13% of O
Medium draft (trial)
Net weight
Maximum authorized load (fuel)
Reload height
Logs length
Minimum flue height
Ø Flue duct
Ø Air inlet
Outer fireplace
Outer fireplace
Outer fireplace
Electrical wiring connection
Fan airflow (unit)
Fan output (unit)
Average temperature of smoke
Type of combustion
Flue liner
Fuel
Humidity fuel logs
Certification year
Certificate number
1.2 Breakdown of delivery components
(Make sure you have all the components described below in relation to the picture on section II of the ANNEXED document)
1. Fireplace's body.
2. Heat-resistant spray paint for touch-ups.
3. Fire grate.
4. Heat-resistant glove.
5. Cleaning cloth for metal painted parts
6. Exterior air inlet kit. (Exterior air inlet connector, connector support, tubular joint, 8x screws and 8xnuts)
7. Tool for handling registers and opening door.
8. Envelope with documents: declaration of performance, energy label, specifications, installation and operation manual, and
Guarantee sheet.
9. +T (flue duct of 1.98 meters of Ø150 (Habit 50V +T / Habit 70A +T) | flue duct of 1.98 meters of Ø180 (Habit 80 +T / Habit
100 +T)
10. Draft limiter
1.3 Diagram of the equipment's measurements
See the ANNEXED document, section I, page 1.
2. REQUIREMENTS PRIOR TO INSTALLATION
ALL LOCAL STANDARDS, INCLUDING NATIONAL AND EUROPEAN REGULATIONS MUST BE COMPLIED WITH UPON
INSTALLATION OF THE EQUIPMENT.
THE INSTALLATION MUST BE PERFORMED BY A PROFESSIONAL. FAILURE TO COMPLY WITH THIS CLAUSE SHALL
EXONERATE THE MANUFACTURER FROM ANY RESPONSIBILITY.
2.1 Ground. Make sure the ground where the appliance will be placed is able to support the weight of the device. If not, you will need
a load spreading plate for the equitable distribution of the equipment's weight. In case of doubt, please consult a specialist.
2.2 Flue liner. It is mandatory to have a smoke-tight Flue liner going from the connecting point of the base to the outside in observation
of the smoke pipe diameter. The good condition and suitability of this smoke pipe must be certified by a professional and
must also observe the relevant national regulations. This Flue liner should not be shared with other devices (see Table 1.1
Technical specifications). In cases of too much draught, when the duct exceeds 7 meters in length, or the measurement exceeds 20
Pa, the draft must be adjusted. To do this, use the second part of the baffle plate, to install it follow the steps: "D.6" to "D.9" or adjust
HABIT 50 V +T
11-13 Pa
2,31 kg/h
5,4 g/s
86,3%
8,7 kW
4 – 9 kW
0,048 %
2
102 mg/Nm
2
51 mg/Nm
2
13 mg/Nm
2
8,4 Pa
154 kg
3 kg
200 mm
300 mm
4000 mm
150 mm
100 mm
(back)
500 mm
(sides)
500 mm
(frontal)
1000 mm
220,8ºC
1880-CPR-008-007-19 1880-CPR-008-009-19 1880-CPR-001-004-19
Model
HABIT 70 A +T
11-13 Pa
2,37 kg/h
6,6 g/s
85,3%
8,8 kW
5,5 – 9,5 kW
0,062 %
3
106 mg/Nm
3
3
51 mg/Nm
3
3
3
22,9 mg/Nm
8,4 Pa
160 kg
4 kg
175 mm
400 mm
4000 mm
150 mm
100 mm
500 mm
500 mm
1000 mm
Silicone hose 3*wire of 1.5 mm
135 m
20 W
220,8ºC
INTERMITENT
NOT SHARED
NATURAL WOOD
12-20 % - two years under cover
2019
HABIT 80 +T
HABIT 100 +T
11-13 Pa
11-13 Pa
2,44 kg/h
3,19 kg/h
6,6 g/s
9,7 g/s
85,3%
9 kW
12,1 kW
6,5 – 11,5 kW
7.5 - 13 kW
0,062 %
0,090%
106 mg/Nm
3
101 mg/Nm
51 mg/Nm
3
59 mg/Nm
3
22,9 mg/Nm
12,1 mg/Nm
8,4 Pa
11,4 Pa
187 kg
220 kg
4 kg
175 mm
175 mm
400 mm
600 mm
4000 mm
4000 mm
180 mm
180 mm
100 mm
100 mm
500 mm
500 mm
500 mm
500 mm
1000 mm
1000 mm
2
3
/h
211,3ºC
196,8ºC
1880-CPR-41-21
86,2%
3
3
3
4 kg
2021
10