Descargar Imprimir esta página

Installation Instructions; Electrical Shock Hazard; Roof Requirements - GE PRC13XHH Serie Manual Del Propietário

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation Instructions

WARNING

ELECTRICAL SHOCK HAZARD

Death or serious injury can result from failure to follow these instructions.
• Disconnect 115VAC and 12VDC power supply before beginning installation and/or servicing
• Ensure product is properly grounded according to the applicable codes
• Replace all parts and panels before operating
A. ROOF REQUIREMENTS AND DETERMINING LOCATION FOR INSTALLATION
Air conditioners covered in this manual are designed
for installation on an RV's roof.
Installation of this air conditioner must be in accordance
with NFPA 1192 and NFPA 70.
For proper installation, there must be a 14
(+/- ") square opening in the roof and ceiling of the
RV.
There must be 2 to 6 inches between the RV ceiling
and roof.
Air conditioners covered in this manual are designed to
fit over preexisting roof vent openings.
If a roof vent opening isn't available, use the following
guidelines:
Figure 1: GE Appliances Outdoor Unit:
13 - 7/8"
32 - 7/8"
Figure 2: GE Profile Outdoor Unit:
Figure 3: GE Appliances Indoor Non-Ducted Unit:
23"
2 -1/2"
10
respect to the RV roof if parked on a flat, level surface.
Roof at the point of installation can have a maximum 15
" x 14
"
degree tilt towards the front or rear of the RV.
Figure 1: GE Appliances Outdoor Unit
Figure 2: GE Profile Outdoor Unit
Figure 3: GE Appliances Indoor Non-Ducted Unit
Figure 4: GE Appliances Indoor Ducted Unit (RAREN)
Figure 5: GE Profile Indoor Non-Ductged Unit
Figure 6: GE Profile Indoor Ducted Unit (RPRED)
27 - 3/4"
21"
(RARMN)
(RPREN)
18"
Center Line of unit
13 - 3/4"
Roof opening
Keep at least 18" free of obstructions at rear of unit.
21.238"
2 - 5/8"
14 - 3/8"
6"
3 - 3/8"
Roof opening
Front
4 - 3/4"
3.834"
49-5000406 Rev. 6

Publicidad

loading