Changing the pilot valve
6102A
– Switch off the mains current and close the water inlet to the faucet.
– Undo the spout's locking screw (19) and pull off the spout (18).
– Undo the cover plate's locking screws (17) with a 2 mm Allen key.
– Detach the sleeve (16) and cover plate (15).
– Detach connectors 10 & 11 from each other.
– Detach connectors 12 & 13 from each other.
– Undo the screws (21) and detach the solenoid valve.
– Undo the screws (22) and detach the pilot valve (25).
– Fasten the new pilot valve in place and reassemble in reverse order.
Changing the solenoid valve membrane
6102A
– Switch off the mains current and close the water inlet to the faucet.
– Undo the spout's locking screw (19) and pull off the spout (18).
– Undo the cover plate's locking screws (17) with a 2 mm Allen key.
– Detach the sleeve (16) and cover plate (15).
– Detach connectors 10 & 11 from each other.
– Detach connectors 12 & 13 from each other.
– Undo the screws (20) and lift off the membrane socket's (26) cover.
– Detach the solenoid valve membrane (27) and clean it or if necessary change for a new one.
– Reassemble in reverse order.
Cleaning/changing the litter filters
6102A
– Switch off the mains current and close the water inlet to the faucet.
– Undo the spout's locking screw (19) and pull off the spout (18).
– Undo the cover plate's locking screws (17) with a 2 mm Allen key.
– Detach the sleeve (16) and cover plate (15).
– Detach connectors 10 & 11 from each other.
– Detach connectors 12 & 13 from each other.
– Unscrew the litter filter (5).
– Clean the litter filter under running water or if necessary change for a new one.
– Reassemble in reverse order.
Installation
6107A, 6109A
(figure 4)
Installation casing
– Attach the installation casing (1) so that the distance between the bottom of the casing and the final
wall surface is 80-85 mm.
– Place the sealing (2) over the casing. It will lie under the final surface material.
– Connect the hot water inlet to the left-hand side and the cold water inlet to the right-hand side G 1/2
connection nipple (3).
– Flush the piping with the enclosed flushing tube (4).
The hot and cold water pipes are flushed separately as follows:
– Unscrew the litter filter (5) from the faucet body and screw the flushing tube in its place.
– Attach the drain hose (ø 13 mm) to the flushing tube.
– Open the corresponding stop valve (7).
– Once the flushing process is completed, close the water inlet to the faucet and screw the litter filter
(5) back in place.
NOTE! Inlet pipes ahead of water fittings must be equipped with a stop valve.