BOGEYBOARD
Operation
The BOGEYBOARD will remain in a "Deep Sleep" mode at all times when no inputs are active.
When any of the No-Volt inputs change state, (Closes or Opens) BOGEYBOARD will wake up and Transmit
an RF signal (within 22mSecs), four times in succession. The LED Flash indicates RF Transmission.
Transmit Type select
Latching Switch Operation (Jumper Link Fitted):
BOGEYBOARD transmits a brief RF signal only when the input is activated or relaxed (State Change).
Using this mode only consumes Transmit power when switch changes state.
If the No-volt switch input is left open or closed BOGEYBOARD will return to "Deep Sleep".
Momentary Switch Operation (Jumper Link Open):
BOGEYBOARD will continuously send an RF signal for as long as the switch input is activated. Using this
mode consumes Transmit power for as long as the switch is active.
Pairing to a Receiver
In any Remote Control the Receiver "learns" the transmitted signal from the BOGEYBOARD, please follow
the Receiver instructions for pairing.
Technical Specifications:
Operating temperature: 0 - 55
Supplied Battery Li-ion CR2032
Electrical Characteristics
Internal Supply Voltage (CR2032)
External Supply Voltage*
Antenna Output Lead Impedance
Time from Input Active to Receiver Output Active
Supply Current
Deep Sleep: all inputs open
Transmitting RF Signal
Sleep: input Closed but after RF Transmission*
Transmit Power
433MHz Version
868 & 918MHz Version
RF Transmit Packet Time
Mechanical Dimensions:
C, Storage Temperature: -10 - 70
o
BOGEYBOARD-T4-6
C
o
Min
Typical
1.8
3
4.5
50
25
0.5
85
+10
+20
22
Max
Units
3.3
Vdc
24
Vdc
Ohms
ms
uA
110
mA
20
uA
dBm
mSecs