periods of inactivity. Provide a visit hatch at the base of the chimney flue to be able to carry out periodic checks and sweeping. The
absence of cleaning will affect the proper functioning of the device.
• Check, by means of appropriate instruments, that the cold draft is at least 4 Pa .
• Imperatively control that a backflow protection of the roof output has been installed, in accordance with the standards in force
• Check the correct configurations using the standard EN 13384-1

CONNECTION TO THE CHIMNEY

• The connection between the stove and the chimney must be made with a pipe 80 or 100 mm diameter with a maximum length
determined by a calculation note.
• For each elbow of 45 °, consider a loss equal to one meter of linear section.
Example: 5m maximum length with 2 elbows = 5m - 2m = 3m
(the tee with tee cap does not count for a elbow)
• The pipe must have a smooth inner surface and resist heat (quality ≥ T200).
• The first change of direction must take place after at least 1.5 meters of vertical section.
• The use of flexible metal pipes, in fiberociment, or aluminum is prohibited. The duct must be as direct and as vertical as possible to
avoid soiling and promote natural draught.
• Provide the basis of the smoke an inspection for periodic controls.
• It is prohibited to connect more than one device to the same smoke duct.
• Maintain the smoke duct at a sufficient distance from any flammable or thermosensible element.
Rear connection
The stove is supplied by default with the rear flue
pipe.
• Secure the adaptor to the back of the stove with
the screws provided and a high temperature
silicone gasket.
• Use a tee with tee cap (80mm input) to connect
the pipe to the stove
Top connection
Since the stove is designed for the evacua-
tion of smoke from the rear, it is necessary to
modify it to connect it from the top.
• remove the left side panel to access the
smoke box.
3
Secure the nozzle to the smoke box with the screws
and a high temperature silicone gasket.
1
Remove the top plate of the smoke box.
4
Remove the lid from the top of the stove.
57
2
Fix the plate at the back of the smoke box by inserting
the gasket.
5
Pass the pipe and fit it on the adaptor using a sleeve
if necessary
EN