Problem
The steriliser does not switch O�.
The feeding bottles are stained at the
end of the sterilisation cycle.
�oise – Incomplete cycle.
The display shows the jug symbol.
IMPORTA�T: If none of the solutions indicated above solves the problem, please contact Artsana Customer Service.
Chicco steriliser is guaranteed free of manufacturing faults
for a period of up to two years from the date of purchase
(i.e. from the date indicated on the retail receipt, or on other
documents proving the date of purchase).
This guarantee does not apply to components subject to
normal wear and tear.
ARTSA�A reserves the right to modify at ant time and wi-
thout prior notice the contents of these instructions.
The reproduction, transmission, copying, as well as the tran-
slation into another language, of any part of these instruc-
tions, are absolutely forbidden without the previous written
authorization by ARTSA�A.
= E quipment certified and approved by IMQ (Ita-
lian Quality Brand)
= Equipment in compliance with the essential requi-
rements laid down in the EC Directives in force.
All manuals and user guides at all-guides.com
TEcHNIcAL cHARAcTERISTIcS
Code 67288
Electronic steriliser for 4 feeding bottles.
Model: 06536
Current: 230V ~ 50Hz
Power: 700 W
Made in China
TROUBLE SHOOTING
Possible cause
There is no power.
The cable plug or cable connector has
not been plugged in correctly, or they
are damaged.
In the appliance there are scale de-
posits.
Excessive scale deposits on the hea-
ting plate.
The display shows the jug symbol.
Incomplete cycle or the cycle does
not start due to:
lack of water or insufficient water to
carry out the cycle, excessive scale
residues on the heating plate.
The water valve on the stopper of the
tank is blocked.
13
Solution
Check that there is power in the
mains.
Check that the plug and connector
have been plugged in correctly, and
that they are in good condition.
Should the product still not work,
contact a qualified technician.
Carry out a descaling cycle as indica-
ted in point 4.
NOTE: There may still be a ten-
dency to the formation of stains,
depending on the level of calcium
contained in the drinking water
used for operating the steriliser.
Carry out a descaling cycle as indica-
ted in point 4.
Switch off the appliance and
fill the tank with water or, if necessa-
ry, descale the plate.
Check that the stopper does not have
excessive scale residues. In this case,
descale the stopper.
= WAR�I�G�
= WAR�I�G� Hot Steam.
= Please read the instructions booklet.
= Warning� Hot surface.
= Instructions for Use.
= Do not dispose of this product as a normal urban
refuse. Dispose of it at an appropriate differen-
tiated refuse collection point, as required by law
in force.