Indicator
ALARM
POWER FAILURE
ON
Alarm LEDs
Airflow Alarm Kit
Light
Description
Red
Too low airflow in the system.
Red
Problem with electrical supply to unit.
Green
Unit active/standby. System is working.
Alarm Status
PSU1
Fan
Fan OFF
OFF
Operating mode:
Normal
ON
Flow=OK
Low flow
ON
Power failure
ON
Low flow
OFF
Power failure
Power OFF
OFF
PSU2
P-SW
Alarm
Constant
Out
Open/
ON
Closed
ON
ON
(Closed)
OFF
ON
(Open)
ON
OFF
(Closed)
OFF
ON
(Open)
OFF
OFF
Relay
Internal
battery
used
OFF
NO
5
6
7
NO
OFF
NO
5
6
7
NO
ON
NO
5
6
7
NC
ON
NO
5
6
7
NC
ON
NO
5
6
7
NC
OFF
YES
5
6
7
NC