Descargar Imprimir esta página

Bosch GLM 80 Professional Manual Original página 20

Ocultar thumbs Ver también para GLM 80 Professional:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 39
20 | English
Digital Laser Measure
Setting accuracy of the laser to the housing, approx.
– Vertical
– Horizontal
Automatic switch-off after approx.
– Laser
– Measuring tool (without measurement)
Weight according to EPTA-Procedure 01/2003
Dimensions
Degree of protection
Measuring rail
Article number
Dimensions
Battery
Rated voltage
Capacity
Number of battery cells
Single measurements per battery charge, approx.
Battery Charger
Article number
Charging time
Output voltage
Charging current
Protection class
A) For measurements from the rear measuring-tool edge, 100 % reflectance of the target (e.g., a white-painted wall), weak backlight and 25 °C oper-
ating temperature. Additionally, a deviation influence of ±0,05 mm/m must be taken into account.
B) For measurements from the rear measuring-tool edge, 10 – 100 % reflectance of the target, strong backlight and – 10 °C to +50 °C operating tem-
perature. Additionally, a deviation influence of ±0.29 mm/m must be taken into account.
C) For measurements with the rear side of the unit as reference, the max. measuring range is ±60°
D) After calibration at 0 ° and 90 ° with an additional grade error of ±0.01 °/degree to 45 ° (max.).
E) In the continuous measurement function, the maximum operating temperature is +40 °C.
F) at 25 °C
G) For a new and charged battery without display illumination and tone signal.
The measuring tool can be clearly identified with the serial number 18 on the type plate.
Product Features
The numbering of the product features shown refers to the il-
lustration of the measuring tool on the graphic page.
1 Display
2 Measuring button
3 Button for grade measurement / calibration **
4 Button for function mode / basic settings **
5 Minus button
6 Button for result / timer function **
7 Button for measured-value list / storage of constant **
8 Button for clearing the internal memory / On/Off **
9 Positioning pin
1 609 92A 0KB | (25.4.14)
GLM 80
Professional
±2 mm/m
±10 mm/m
20 s
5 min
0.14 kg
51 x 111 x 30 mm
IP 54 (dust and splash water
protected)
Li-Ion
3.7 V
1.25 Ah
25000
2 609 120 4..
approx.3 h
5.0 V
500 mA
10 Button for selection of the reference level
11 Plus button
12 Button for length, area and volume measurement
13 Charge socket cover
14 Socket for charge connector
15 Fixture for carrying strap
16 Laser beam outlet
17 Reception lens
18 Serial number
19 1/4" thread
20 Laser warning label
21 Charge connector
GLM 80+R60
Professional
F)
±2 mm/m
F)
±10 mm/m
51 x 111 x 30 mm
IP 54 (dust and splash water
protected)
3 601 K79 000
58 x 610 x 30 mm
1
G)
2 609 120 4..
approx.3 h
/II
Bosch Power Tools
F)
F)
20 s
5 min
0.14 kg
Li-Ion
3.7 V
1.25 Ah
1
G)
25000
5.0 V
500 mA
/II

Publicidad

loading

Este manual también es adecuado para:

Glm 80+r60 professional