Descargar Imprimir esta página

Baumer OT500 Serie Manual De Instrucciones

Publicidad

Enlaces rápidos

Photoelectric sensors
10.2022/ Version 2.0
OT500
qTarget
qTeach
www.baumer.com
Baumer Electric AG - CH-8501 Frauenfeld
Phone +41 (0)52 728 1122 - Fax +41 (0)63 739 1144
Related Models
OT500 Models:
OT500.D* (Distance measuring sensors)
OT500.G* (Background suppression sensors)
OT500.S* (SmartRefl ect light barriers)
More Information related to these
products can be found on our website
(CAD, Beamcharts, CoC, Drawings, IODDs ...)
Englisch
www.baumer.com
LED Indication
Legend
LED on
1
LED fl ashing 1 Hz
LED fl ashing 2 Hz
2
8
LED fl ashing 8 Hz
Only sensors with 2 outputs do have a red LED
Teach-In Description Level 1 & 2
OT500.D, Distance measuring
OT500.G, Background suppression
1-Point Teach
1-Point Teach: Output 1
Sets the switchpoint at the position of
Sets the switchpoint at the position of
the object +TPO* (teach point off set)
the object + TPO* (teach point off set)
TPO: See packaging (typ. 5%)
TPO: See packaging (typ. 5%)
+TPO*
+TPO*
Sensing direction
Sensing direction
Teach-Position
Teach-Position
Scanning Range / Window Teach
1-Point Teach: Output 2
Set the scanning range related
Sets the switchpoint at the position of
to the analogue value. Output 1
the object + TPO* (teach point off set)
is active if an object is within the
TPO: See packaging (typ. 5%)
scanning range
10 V /
+TPO*
10 V /
20 mA
20 mA
0 V /
0 V /
4 mA
Sensing direction
4 mA
A > B
Teach-Position
A < B
*This value is adjustable by IO-Link. Please check the IO-Link manual available on www.baumer.com
Teach-in Instruction
Enter Teach Level
- Place ferromagnetic tool as shown right to
activate qTeach
or connect Teach-In wire to +Vs
®
- The blue LED gets brighter if tool / Teach-In is
recognized properly
- Remove after n sec for desired level
A TAP is a short touch (>100 ms) of the tool as
shown right
2 sec / Level 1
1- Point Teach
2 2
OT500.D
Scanning Range /
4 sec / Level 2
Idle 60 sec
Window Teach
2 2
OT500.G with 2 outputs
1- Point Teach
Idle 60 sec
Output 2
Indication Logic
6 sec / Level 3
Output Logic
2
2 2
After each defi ned idle time, the sensor returns to
operation mode.
Place tool >2 sec : Leave Teach-In immediately
without changes
8 sec / Level 4
Factory Reset
Do nothing for factory reset
1
1 1
Models with IO-Link
11247884
EN
IO-Link Process Data Input
DE
16
8
IntegerT(16)
IntegerT(8)
FR
Measurement
Scale
IT
Data Channel
7
6
5
(MDC)
ES
SSC4
CN
SSC1/2/4: Switching Signal Channels
MDC:
Distance value, quality value or switch counts
(selectable)
Quality:
The quality bit signals a weak signal
Alarm:
The alarm bit signals a problem with the
confi guration or the functionality of the sensor
Scale:
Factor by power of ten, applicable to the value of
the Measurement Data Channel (MDC)
Available Commands:
Teach-In commands, light emission on/off , Find Me (locating
sensor) and more
®
Available Parameters:
Switching point, switching hysteresis, output function, time
®
fi lters, measured value fi ltering, analog output characteristic,
qTeach lock time, LED status indicators and more
Available Additional Data:
Switch counts, temperature, boot cycles, operating hours,
device temperature, operating voltage, histograms
Connection Diagrams
M12
+Vs
2
1
3
4
0V
OT500.D
OT500.G
1 - Brown BN
+Vs
2 - White WH
Output 2 or
Analog U or I
complementary to
Output 1
3 - Blue BU
0 V
4 - Black BK
IO-Link* / Output 1
5 - Grey GY
Teach-in / control
*Only models with IO-Link
See packaging label for the specifi c wiring of your product
- Disconnect power before connecting the sensor.
- Voltage supply according UL 1310, Class 2
or device shall be protected by an external R/C or listed fuse, rated max.
30 VAC/3A or 24 VDC/4A
Operating Mode
LED Indicators
Green
Power on
Short circuit
1
Output 1 active
Output 1 signal close
to threshold
Output 2 active
Output 2 signal close
to threshold
qTeach not locked
Teach-in mode
see Teach-in Instruction
OT500.S, SmartRefl ect light barriers
Optional Teach-In methods*
Pre-confi gurable via IO-Link
1-Point Teach
Teaches the position of the
Window mode (OT500.D, OT500.G)
reference (distance)
Level 1 / 1-Point Teach:
Sets a window of +/- 5% (TPO*) around
Tolerance: See packaging (typ.+/- 10%)
the position of the object
Tolerance +/-*
Level 2 / 2-Point Teach:
sensing range, Sa
Sets a window of +/- 5%* around the
Reference
position of the object
Not active
For SmartRefl ect Light barriers, the
teach level 2 is not active
If level 2 is entered, the sensor leaves
the level immediately without any
changes
General Information
- qTeach
locks 5 min after power up*
®
- If locked, qTeach
can be reactivated by re-apply-power or
®
by connecting the Teach-In wire for >15 sec. to +Vs
- External teach-in is always possible (no locking)
- In teach mode the output changes to 0V
- During operation the teach wire should be connected to 0V
- For external Teach-In connect Teach-In to +Vs
Idle 60 sec
Place object & TAP
OT500.S
Align the sensor to
Alignment Aid
Idle 60 sec
the reference & TAP
Place object at
Place object at
Idle 60 sec
position B & TAP
position A & TAP
Place object & TAP
TAP to change
NO, out 1
Idle 4 sec
setting
NC, out 1
OT500.G
Indication Logic
Optional: Hold 2
sec to change to
NO, out 2
output 2
NC, out 2
Teach-in OK
X
Teach-in NOK
Alignment Aid
OT500.S Lichtschranken verfügen über eine Ausrichthilfe.
Diese ist im Teach Level 1 integriert und zeigt die Stärke des
0
empfangenen Signals an.
8 bit
Baumer specifi c
4
3
2
1
0
OT500.S light barriers are equipped with an alignment aid,
Alarm Quality SSC2
SSC1
which is integrated in Teach Level 1.
The alignment aid indicates the strength of the received
signal.
Les barrières lumineuses OT500.S sont équipées d'un outil
d'aide à l'alignement, qui est intégré au niveau 1 de la procé-
dure de teach.
L'aide à l'alignement indique la force du signal reçu.
Le barriere fotoelettriche OT500.S sono dotate di indicazione
di corretto allineamento. Questa funzione è integrata nel
livello 1 di Teach-In e viene indicata l'intensità del segnale
ricevuto.
Las barreras de luz OT500.S están equipadas con una ayuda
de alineado integrada en el Nivel 1 de Teach.
La ayuda de alineado indica la potencia de señal recibida.
OT500.S轻障的配备了对准辅助功能, 集成在设定级别1中.
对准辅助表明了接收信号的强度.
Mounting Instructions
5
It is recommended that the object to be detected approaches the active area of
OT500.S
the sensor from the side.
This may avoid malfunctions caused by defl ection of the light beam at edges.
Exception: Sensors with line beam
Output 2 (quality
bit) or
complentary to
Output 1
LED Anzeige
EN
Yellow
Red
Blue
8
8
Nur Sensoren mit 2 Ausgängen verfügen über eine rote LED
Teach-In Beschreibung Level 1 & 2
OT500.D, Distanzmessend
1-Punkt Teach
Setzt den Schaltpunkt an der Position
des Objektes + TPO*
(Teach point off set, typ. 5%)
+TPO*
Sensing direction
Teach-Position
Messbereich / Fenster Teach
Defi niert den mit dem analogen
Ausgang verknüpften Messbereich.
Ausgang 1 ist aktiv, wenn sich ein
Objekt innerhalb des Messbereichs
befi ndet
10 V /
20 mA
0 V /
4 mA
A < B
*Dieser Wert kann per IO-Link verändert werden. Weitere Details fi nden Sie im IO-Link Manual verfügbar auf www.baumer.com
Teach-in Anleitung
Teach Level auswählen
- Platziere das ferromagnetische Werkzeug wie
rechts dargestellt um qTeach® zu aktivieren oder
verbinde die Teachleitung mit +Vs
- Die blaue LED leuchtet auf, wenn das
Werkzeug korrekt erkannt wird
- Nach n Sek. entfernen, um das gewünschte Level
auszuwählen
Ein TAP ist eine kurze Berührung (>100 ms) des
Werkzeugs
2 sec / Level 1
2 2
4 sec / Level 2
2 2
6 sec / Level 3
2
2 2
Nach der defi nierten Idle-Zeit kehrt der Sensor in
den Betriebsmodus zurück.
TAP to change
setting
Werkzeug platzieren >2 Sek.: Verlasse Teach-In
ohne Änderungen.
8 sec / Level 4
8
8
8
8
1
1 1
Sensor ausrichten, schnelles Blinken, besserer Empfang
Align sensor, faster fl ashing, better reception
Aligner le capteur, clignotement plus rapide, meilleure est la
réception
Allineamento del sensore: più è veloce il lampeggiamento
tanto più è forte il segnale
Sensor alineado, parpadeo más rápido, mejor recepción
对准传感器,闪烁越快,接收得更好
qTarget
The Baumer design aligns the sensor's light beam to
the fi xing holes (qTarget
This allows a fast and easy installation without
fi ne-tuning as well as fast exchange.
Legende
LED leuchtet
1
LED blinkt 1 Hz
2
LED blinkt 2 Hz
8
LED blinkt 8 Hz
OT500.G, Hintergrundausblendung
OT500.S, SmartRefl ect Lichtschranken
1-Punkt Teach: Ausgang 1
1-Punkt Teach
Setzt den Schaltpunkt an der Position
Lernt die Position der Referenz ein
des Objektes + TPO*
(Distanz)
(Teach point off set, typ. 5%)
Tolerance:
Siehe Verpackung (typ. +/- 10%)
+TPO*
Sensing direction
Teach-Position
1-Punkt Teach: Ausgang 2
Nicht aktiv
Setzt den Schaltpunkt an der Position
Für die SmartRefl ect Lichtschranken ist
des Objektes + TPO*
das Level 2 nicht aktiv
(Teach point off set, typ. 5%)
Wird das Teach-Level 2 ausgewählt,
verlässt der Sensor den Teach-In
+TPO*
10 V /
Modus ohne jegliche Änderungen
20 mA
0 V /
Sensing direction
4 mA
Teach-Position
A > B
1-Punkt Teach
OT500.S
Ausrichthilfe
OT500.D
2-Punkt Teach /
Objekt platzieren an
Idle 60 sec
Fenster
Position A & TAP
OT500.G with 2 outputs
1-Punkt Teach
Idle 60 sec
out 2
Indikation Logik
TAP um Einstel-
Ausgangslogik
NO, out 1
lung zu ändern
NC, out 1
OT500.G
Optional: 2 sec
halten -> zu Aus-
wechseln
gang 2
Werkseinstellungen
Keine weiteren Eingriff e nötig
n
Faster fl ashing
→ stronger signal
®
®
).
Betriebsmodus
DE
LED Indikatoren
Grün
Gelb
Rot
Blau
Betriebsanzeige
1
Kurzschluss
Ausgang 1 aktiv
Ausgang 1 Signal
8
nahe der Schwelle
Ausgang 2 aktiv
Ausgang 2 Signal
8
nahe der Schwelle
qTeach verwendbar
siehe Teach-in Anweisung
Teach-in Modus
Optionale Teach-In Modi*
Voreinstellbar per IO-Link
Fenster-Modus (OT500.D, OT500.G)
Level 1/ 1-Punkt Teach:
Defi niert ein Fenster à +/- 5% (TPO*) um
die Position des Objektes
Tolerance +/-*
Level 2 / 2-Punkt Teach:
sensing range, Sa
Defi niert ein Schaltfenster, innerhalb wel-
Reference
chem ein Objekt erkannt werden soll
Allgemeine Information
- qTeach
verriegelt 5 min nach dem Einschalten*
®
- Falls gesperrt, kann qTeach® durch ein erneutes Einschalten oder
durch den Anschluss der Teach-In-Leitung für >15 Sek. an +Vs reaktiviert
werden
- Externes Teach-In ist immer möglich (keine Verriegelung)
- Im Teachmodus wechselt der Ausgang auf 0V
- Im Normalbetrieb muss die Teachleitung auf 0V gelegt werden
- Für externes Teach-in, Teachleitung entsprechend mit +Vs verbinden
Objekt platzieren
Idle 60 sec
& TAP
Den Sensor zur
Idle 60 sec
Referenz ausrichten
& TAP
Objekt platzieren an
Idle 60 sec
Position B & TAP
Objekt platzieren
& TAP
Idle 4 sec
Indikation Logik
TAP um Einstel-
NO, out 2
lung zu ändern
NC, out 2
Teach-in OK
X
Teach-in NOK
8
8
8
8

Publicidad

loading

Resumen de contenidos para Baumer OT500 Serie

  • Página 1 A > B A < B *Dieser Wert kann per IO-Link verändert werden. Weitere Details fi nden Sie im IO-Link Manual verfügbar auf www.baumer.com *This value is adjustable by IO-Link. Please check the IO-Link manual available on www.baumer.com Teach-in Instruction...
  • Página 2 A < B A > B * Cette valeur est ajustable via IO-Link. Consultez le manuel IO-Link disponible sur www.baumer.com *Questo valore è modifi cabile via IO-Link. Consultare il manuale IO-Link disponibile sul sito www.baumer.com Instructions Teach-In Instrucciones Teach-In Entrée en mode Teach: Information Générale...

Este manual también es adecuado para:

Ot500.dOt500.gOt500.s