- The electrical system is provided with a differential switch with I Δn ≤ 30 mA and
that the earth system is efficient.
ELECTRICAL CONNECTIONS
Attention: always respect the safety regulations! Electrical installation must be
carried out by an expert, authorized electrician, who takes on all responsibility.
The system must be correctly and safely earthed as required by the regulations in
force.
If a plug-connected pump is connected to an electric installation where an
electrical circuit breaker (voltage sensing ELCB, residual-current device
RCD or residual-current circuit device RCCB) is used as an additional protection,
this circuit breaker must be marked with the first or both of the symbols shown
below. If the pump is terminal-connected, the circuit breaker must be marked
with both of the symbols below:
If the appliance is not fitted with means for disconnection: means for disconnection
must be incorporated in the fixed wiring in accordance with the regulation in force
in the country where the product is to be installed.
The thermal magnetic circuit breaker must be correctly sized.
MAINTENANCE
Cleaning and user maintenance shall not be made by children without supervision.
Before starting any work on the system, before starting to look for faults it is
necessary to disconnect the power supply to the pump (take the plug out of the
socket).