Descargar Imprimir esta página

SICK WTF12L Manual De Instrucciones página 32

Ocultar thumbs Ver también para WTF12L:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 47
OPERATING INSTRUCTIONS
en
6
Commissioning
6.1
Alignment
6.2
Check the application conditions
32
O P E R A T I N G I N S T R U C T I O N S | WTF12L/WTF12V
Table 3: Push-pull, PNP, NPN
PNP
Push-pull
NPN
PNP
Push-pull
NPN
Alignment with foreground suppression
Align the sensor with the background. You must ensure that the optical opening (front
screen) of the sensor is completely clear
Figure 3: Alignment on background
WTF12L/WTF12V are photoelectric proximity sensors with foreground suppression. The
photoelectric proximity sensor requires a background as a reference. The remission
factor and position of the background should remain as uniform as possible. The
maximum distance (x) between the photoelectric proximity sensor and background as
well as the minimum object height (y) must be upheld. As a rule, a WTF12L/WTF12V is
used to detect very flat objects on a conveyor belt.
+ (L+)
Q ≤ 100 mA
Push-pull
‒ (M)
+ (L+)
Q ≤ 100 mA
Push-pull
‒ (M)
[see figure
3].
+ (L+)
PNP
Q ≤ 100 mA
NPN
‒ (M)
+ (L+)
PNP
Q ≤ 100 mA
NPN
‒ (M)
8027710/2022-04-12 | SICK
Subject to change without notice

Publicidad

loading

Este manual también es adecuado para:

Wtf12v