Operating Instructions
Safety Switch STP-TW... (Twin)
30
h
16
<39>
<42>
30
With plug connector SR11
With lateral plug coonnector
Fig. 3: Dimension drawing for STP-TW...
Hinged actuator S-OU-SN
20
20
35,50
35,50
Fig. 4: Minimum door radii
Necessary minimum travel + perm. overtravel
Approach direction
Horizontal (h)
Vertical (v)
0,3
h
<72>
Ø 5.3 (2x)
for M5 x 35 mm
ISO 1207/ISO 4762
Do not use these
mounting holes!
M = 0.8 Nm
red
green
LED module (optional) enclosed
separately.
Observe assembly instructions.
30
<40>
Ø 5.3 (2x)
for M5 x 35 mm
ISO 1207/ISO 4762
0,3
4
4
20
20
ca. 28
SR11
20
35,50
35,50
Actuator S
standard
24.5 + 5
24.5 + 5
Auxiliary key release
Auxiliary release
Locking screw
Auxiliary release with triangu-
lar wedge
(2 triangular keys included)
Hinged actuator S-LR-SN
20
9
33
With wire front release (bowden)
Key to symbols
Guard locking ready for operation
/
Guard locking released
/
Door radius,
Actuator
min. [mm]
Actuator S-G...
Actuator S-W...
Hinged actuator S-OU...
Hinged actuator S-LR...
300
300
200
200