NOTICES
When using the device, read the instructions carefully and pay special attention to the „warning" content. Follow the „warning" in-
structions.
• Only the use of the device with the enclosed cables complies with the safety standards. If cables are damaged, replace them with new
ones of the same model or electrical specification.
• Before use, check the instrument and attached accessories to avoid damage or irregularities.
• Do not touch an unused input connector while measuring.
• Care must be taken when measuring voltages above 60 V DC and 30 V AC
• When the measured range cannot be determined, set the function range switch to the maximum range. Do not exceed an input limit
that is regulated by each range.
• Do not measure a voltage higher than the permissible input value.
• Before turning the function range switch, hold the plug and the circuit in measurement in the open circuit state.
• Before measuring the online resistance, turn off all power supplies in the circuit and release the charge at both ends of the capacitor.
• Do not expose the device to strong light, high temperature or humidity.
• Do not touch exposed wires, connectors or circuits during measurement.
MAINTENANCE
• After opening the rear cover of the unit, make sure that the plugs are disconnected from the measured circuit.
• Use only a damp cloth and a small amount of detergent to clean the device and do not use chemical solvents to clean the housing
of the meter.
• If any irregularities are observed, stop using the device and send it for repair.
12
11
10
8
9
8
STRUCTURE
1
1. NCV induction area
2. Alternating Current Jaw
3. Flashlight
4. Function selection switch
5. Flashlight button: touch to turn the flashlight on/off.
2
6. Backlight and data lock button. Press the „HOLD"
key, the last reading measured on the display will
be stored; displays „
again, the instrument will return to its normal state.
3
Press and hold the button
the backlight on/off.
7. Display 3 5/6 digits, letter height 12 mm.
8. INPUT input socket
It measures voltage, resistance, positive diode drop
and circuit switching on and off, red plug.
9. COM input socket
4
Except for AC, negative black plug.
10. VFC. The measurement function of the inverter:
When measuring voltage or AC power, touch this
button to turn the VFC function on/off.
11. SEL selection button
During the measurement, the button
5
switch between DCV and ACV.
When measuring the gearbox, the button is used to
6
switch between resistance, diode measurement and
on/off measurement.
12. Trigger
7
Push the trigger, the terminal head will open: release
the trigger, the terminal head will close automatically.
Adres producenta/ Adresse des Herstellers/ Manufacturer's Address/ Адрес производителя
GTV Poland Sp. z o.o. Sp. k., ul. Przejazdowa 21, 05-800 Pruszków
H
", press the „HOLD" button
for 2 seconds to turn
is used to