TF Tablet Feeder | Installation & Operation Manual
Polaris
AutoClear
®
™
DO NOT INSTALL chlorine feeder before the heating system. Damage
to the heating system may occur. The feeder is designed for permanent
installation in the return line of the pool and must always be installed after
the heater, pool cleaner, valves, mineral sanitizer etc. If there is no heater
then install the feeder after the filter and all other equipment.
In order to prevent risk of serious property damage, injury or death:
Wear eye and skin protection while maintaining or servicing this unit.
Do not inhale fumes from the chlorinator or chemical container.
Chlorine feeder may be under pressure. Use caution removing cover.
1. Make sure all pumps and timer switches are OFF.
2. Place T-gasket into groove on inlet.
3. Install the 1-1/2" threaded adapter to the filter valve or system plumbing then
couple the feeder inlet to the 1-1/2" threaded adapter using the split union
nut.
4. Install the outlet connection:
•
If the pool is plumbed with corrugated or flex hose, install the hose
adapter provided in the outlet. (Fig. 3a) Take the 1-1/2" hose adapter
and install in the outlet with Teflon tape (not provided).
•
If the pool is plumbed with 1-1/2" PVC pipe, use bushings installed
directly into the outlet side of the feeder and install the union fitting
provided for the inlet. (Fig. 3b)
ENGLISH
CAUTION
WARNING
Page 5