Product Information
HIntended use
The indoor unit is intended for installation inside the building with
connection to an outdoor unit and further system components, e.g.
controls.
The outdoor unit is intended for installation outside the building with
connection to an indoor unit or units and further system components,
e.g. controls.
The air conditioning system is intended for commercial/residential use
only where temperature deviations from adjusted set points do not lead
to damage of living beings or materials. The air conditioning system is not
suitable to set and maintain desired absolute humidity levels precisely.
Any other use is considered inappropriate. Any damage that may result
from misuse is excluded from liability.
For installation at special locations (underground garage, mechanical
rooms, balcony or at any semi-open areas):
▶ First refer to the requirements for the installation site in the technical
documentation.
HGeneral dangers posed by the refrigerant
▶ This appliance is filled with refrigerant R32. If the refrigerant gas gets
into contact with fire, it may generate toxic gas.
▶ Thoroughly ventilate the room if refrigerant leaks during the
installation.
▶ Check the tightness of the system following the installation.
▶ Do not to let any other substance than the specified refrigerant (R32)
into the refrigerant cycle.
HSafety of electrical devices for domestic use and similar
purposes
The following requirements apply in accordance with EN 60335-1 in
order to prevent hazards from occurring when using electrical
appliances:
"This appliance can be used by children of 8 years and older, as well as
by people with reduced physical, sensory or mental capabilities or
lacking in experience and knowledge, if they are supervised and have
been given instruction in the safe use of the appliance and understand
the resulting dangers. Children shall not play with the appliance.
Cleaning and user maintenance must not be performed by children
without supervision."
"If the power cable is damaged, it must be replaced by the manufacturer,
its customer service department or a similarly qualified person, so that
risks are avoided."
HHandover to the user
When handing over the air conditioning system, explain the operation
and operating conditions to the user.
▶ Explain operation – with particular emphasis on all safety-related
actions.
▶ Highlight the following points in particular:
– Point out that modifications or repairs may be carried out only by
an approved contractor.
– To ensure safe and environmentally compatible operation, an
annual inspection, and also cleaning and maintenance if required,
must be carried out.
▶ Point out the possible consequences (personal injury and possible
danger to life or material damage) of not carrying out inspection,
cleaning and maintenance correctly, or omitting it altogether.
▶ Hand over the installation and operating instructions to the user for
safekeeping.
1.3
Notices regarding these instructions
The figures are shown together at the end of these instructions. The text
contains references to the figures.
Depending on the model, the products may be different to those shown
in these instructions.
50
2
Product Information
2.1
Declaration of conformity
The design and operating characteristics of this product comply with the
European and national requirements.
The CE marking declares that the product complies with all the
applicable EU legislation, which is stipulated by attaching this
marking.
The complete text of the Declaration of Conformity is available on the
Internet: worcester-bosch.co.uk.
2.2
Scope of delivery
Key to Fig. 1:
[1]
Outdoor unit (filled with refrigerant)
[2]
Indoor unit (filled with nitrogen)
[3]
Cold catalyst filter
[4]
Drainage elbow with gasket (for outdoor unit with floor or wall
mounting bracket)
[5]
Remote control
[6]
Remote control holder with fixing screw
[7]
Fixing materials (5 screws and 5 wall plugs)
[8]
Set of printed documents for product documentation
[9]
5-core communication cable (optional accessory)
[10] 4 anti-vibration couplings for the outdoor unit
2.3
Product dimensions and minimum clearances
2.3.1
Indoor unit and outdoor unit
Figures 2 to 4.
2.3.2
Refrigerant pipes
Key to Fig. 5:
[1]
Gas-side pipe
[2]
Liquid-side pipe
[3]
Siphon-shaped elbow as oil separator
If the outdoor unit is positioned higher than the indoor unit, install a
siphon-shaped elbow on the gas side after no more than 6 m and every
6 m thereafter ( Fig. 5, [1]).
▶ Observe maximum pipe length and maximum difference in height
between indoor unit and outdoor unit.
Maximum pipe
length
CL3000i 26 E
CL3000i 35 E
CL3000i 53 E
CL3000i 70 E
1) Gas side or liquid side
2) Measured from bottom edge to bottom edge.
Table 62 Pipe length and difference in height
Unit type
Liquid side [mm]
CL3000i 26 E
6.35 (1/4")
CL3000i 35 E
6.35 (1/4")
CL3000i 53 E
6.35 (1/4")
CL3000i 70 E
9.53 (3/8")
Table 63 Pipe diameter depending on appliance type
Climate 3000i – 6721823680 (2023/01)
Maximum difference
1)
2)
[m]
in height
[m]
≤ 25
≤ 10
≤ 25
≤ 10
≤ 30
≤ 20
≤ 50
≤ 25
Pipe size
Gas side [mm]
9.53 (3/8")
9.53 (3/8")
12.7 (1/2")
15.9 (5/8")