3.3
Data plate description
The data plate certifi es the country where the product is
intended to be installed.
The data plate contains the following data:
Abreviation/
Description
symbol
Country code:
Country where the product is intended to be
"GB"
installed
Commercial name of the product and its serial
Serial-no
number
Code
Product code of the appliance
PMS
Central heating maximum pressure
V/Hz
Electrical voltage / frequency
A
Current
W
Maximum electrical consumption
IP
Electric protection index
See chapter "CE label"
See chapter "Recycling "
4
Mounting and installation
i
Notes
All the drawings dimensions are shown in
mm.
4.1
Preparing the mounting and
installation
4.1.1
Delivery and installation on site
4.1.1.1
[product] unpack
∙ Remove the product from its box.
∙ Remove the protective fi lm from all parts of the product.
4.1.1.2
Check scope of delivery
∙ Please check the scope of delivery for completeness.
- 1 Hydraulic module
- 1 bag of accessories
- Attachment bracket (x1)
- Flat gasket 1" (x6)
- Flat gasket 1"1/4 (x2)
- 1 bag of documents (1 operating and installation)
MOUNTING AND INSTALLATION
4.1.2
Observing distances and mounting
clearances
4.1.2.1
Product and connection dimensions
3 6
0
180
87
81.5
4.1.2.2
Distance to infl ammable parts
∙ Make sure that no item that can easily catch fi re is in
direct contact with the components, which may reach a
temperature greater than 80°C.
∙ Make sure that there is a minimum distance of 200 mm
between items that can easily catch fi re and the hot
surfaces.
0
2 5
180
101
40
40
81.5
EN
6