security
Example of connection with the TM600 or ALADIN5X burglar central unit
Set the relay in MONOSTABLE operating mode.
Example of connection with burglar central units of TM or PROTEC series (excl. PROTEC5X)
Set the relay in BISTABILE operating mode.
Example of connection with automation central units
Set the relay in MONOSTABLE operating mode.
PROGRAMMATION
The system uses two six-digit codes that can be customised by the user. Each code can activate
the relative output relay, or both. To access the programming mode, move the jumper 1 (JMP1 as
shown in picture) to ON position.
Codes programming
Enter the channel on which to program the code: (1) or (2). The red LED on the keyboard will
turn on.
Enter the code consisting of 1 to 6 digits. All the digits can also be the same number.
Enter (#) to store the code or (*) to quit the operation.
Repeat the sequence to change the code or to program the code of the other channel.
DO NOT USE TWO IDENTICAL CODES.
KB-KB24 - Electronic keyboard control system
KB
KB
KB24
N4
N1
12Vdc
CKI
ON/OFF
V
R
12Vdc
LED
KEY
7