Descargar Imprimir esta página

Uline H-10420 Manual De Instrucciones página 4

Publicidad

Idiomas disponibles

Idiomas disponibles

ACCESSORIES/TOOLS (OPTIONAL)
Use for upholstery cleaning and hard-to-reach areas.
1. Attach recovery hose to recovery hose connection
of vacuum shoe.
DAILY
• Check the spray jet for blockage and uniform spray
pattern. Remove jet and blow through to clean. Do
not use a pin as this may cause damage to the jet.
• Check and remove any debris or lint buildup from
the vacuum head, brush and brush housing.
• Wash tanks with clean water after each use. Pour
clean water into solution tank and spray through spray
tip to clear chemical residue from the pump, lines and
spray tip. Run machine for a few minutes to aid drying
and prevent bacteria and odors.
OPERATING ISSUE
Motor is not running
Loss of suction
Brush malfunction
Spray jet malfunction
PAGE 4 OF 12
OPERATION CONTINUED
MAINTENANCE
TROUBLESHOOTING
CAUSES
Power not reaching main switch.
Defective power cord.
Blown fuse or tripped circuit breaker.
Vacuum head blocked.
Hoses blocked.
Recovery tank not properly sealed.
Belt broken.
Brush jammed.
Jet blocked.
Solution filter blocked.
1-800-295-5510
2. Connect accessory solution hose to the solution
hose connection at the front of the machine.
NOTE: Push back the locking ring to secure
hose to machine.
3. Turn on vacuum and pump.
WEEKLY
Inspect hoses, hose cuffs, main cable, plug, switches
and rubber seal on the recovery tank lid for damage.
NOTE: Store the unit with the recovery tank lid
open or removed.
CAUTION: Protect unit from freezing. Damage
from freezing could cause machine to
malfunction.
Check power supply, fuses and circuit
breaker.
Replace with 14 gauge cord.
Reset circuit breaker.
Visually inspect and clear blockage.
Visually inspect and clear blockage.
Check tank for damage or adjust lid
for proper fit.
Replace belt.
Visually inspect and clear blockage.
Visually inspect and clean according
to maintenance instructions.