H-3030, H-3784
EVAPORATIVE COOLER
WHAT IS EVAPORATIVE COOLING?
When trying to understand evaporative cooling, it may
be best to think of air as being like a sponge, meaning
that air has an ability to absorb moisture that it comes
in contact with. The amount of moisture that the air will
absorb depends on the state of the air, or specifically,
how much moisture the air already contains and the
temperature of the air. If the air is warm and contains
only a small amount of moisture, it will more readily
absorb moisture. As air cools, its volume decreases, and
with it, its ability to absorb moisture decreases.
The term "relative humidity" describes the quantity of
water in the air in relation to its total capacity.
Any volume of air at any given temperature has an
ability to hold a certain quantity of moisture. If the air
contains 20% of its total capacity to hold moisture, the
relative humidity is said to be 20%. Whereas, a humidity
of 100% indicates that the air at this temperature and
pressure is holding all the moisture it can. If the air has
less that 100% relative humidity when entering the unit,
then it has the ability to hold more moisture, and will
thus evaporate more water and cool more effectively.
When describing the amount of moisture in the air, the
term relative humidity is used because the absorption
capacity of air changes relative to air temperature. The
warmer the air, the more absorbent it becomes, and
can consequently hold more water. That is to say that
air that has a 100% relative humidity can hold no more
water vapor. However, if the air is heated, it expands,
and, as a result, the relative humidity decreases even
though the total amount of water vapor in the air has
not changed. As a result, we must describe the level of
humidity relative to its maximum capacity. Is it a 50˚F
sponge or an 80˚F sponge? An 80˚F sponge will hold
more water at 50% humidity than a 50˚F sponge.
PAGE 1 OF 21
1-800-295-5510
uline.com
INTRODUCTION
How is cooling produced? In order to evaporate water,
heat (energy) is required. In fact, the evaporation of one
gallon of water requires almost 8,700 BTU's. Where does
this heat come from? The heat comes from whatever the
water is in contact with as it evaporates. This could be a
hot sidewalk, your body, a tree, or from the air itself.
As the heat is removed from an object, the temperature
of that object is decreased. In the case of the unit, heat
is removed from the air, reducing the temperature
of the air.
It is important to realize that the temperature of the
water does not have a great effect upon the cooling
produced by the evaporation. If you were to place
a gallon of 50˚F water on a warm sidewalk, it would
consume 9,000 BTU's during its evaporation, thus
making the sidewalk 9,000 BTU's cooler. A gallon of
90˚F water would produce 8,700 BTU's of cooling, only
a 3% difference in the total result. This translates into a
difference of less than 1˚F in the performance of the unit.
The following table demonstrates the BTU's removed from
the air based on a given amount of water evaporated
in an hour by the unit.
U.S. GALLON/HOUR
10 (3.8 liters or 8.3 Imperial Gallons)
12 (45.4 liters or 10.0 Imperial Gallons)
14 (53.0 liters or 11.7 Imperial Gallons)
In simple terms, evaporative cooling is nature's way of
cooling. The unit utilizes the same phenomenon, but in
an extremely efficient manner.
Para Español, vea páginas 8-14
Pour le français, consulter les pages 15-21
TOTAL BTU'S REMOVED
87,000
104,400
121,800
0621 IH-3030

Publicidad

loading

Resumen de contenidos para Uline H-3030

  • Página 1 Para Español, vea páginas 8-14 Pour le français, consulter les pages 15-21 H-3030, H-3784 1-800-295-5510 uline.com EVAPORATIVE COOLER INTRODUCTION WHAT IS EVAPORATIVE COOLING? How is cooling produced? In order to evaporate water, heat (energy) is required. In fact, the evaporation of one When trying to understand evaporative cooling, it may gallon of water requires almost 8,700 BTU's.
  • Página 2 ELECTRICITY stop and the inlet connections may now be visually checked for leaks. Pay particular attention to the hose WATER CONNECTION (Applies only to H-3030) connection into the float valve and the connections into the brass inlet fitting. NOTE: Unit must be in upright and level position.
  • Página 3 SETUP CONTINUED ELECTRICAL CONNECTION When making electrical connections ensure that local and national codes are adhered to. Use only with GFCI NOTE: Unit must be in upright position with Protected Receptacles. cooling pads installed! Please refer to the barcode product label on the side of This unit utilizes a single power cord and control switches.
  • Página 4 The rugged, the evaporative cooler. Additional boxes of mineral corrosion-resistant construction of the unit and industrial treatments can be purchased by ordering Uline model grade components make for the low maintenance number H-6108. characteristics. In exceedingly dusty or dirty...
  • Página 5 TROUBLESHOOTING TROUBLESHOOTING If you have a complete understanding of all the systems of the unit and how they depend on each The most common problems encountered with unit are other, it becomes much simpler to define and solve any operational problems. The unit consists of three systems. problems.
  • Página 6 TROUBLESHOOTING CONTINUED WATER INLET SYSTEM PROBLEM CHECK SOLUTION Floor near the unit is wet. Water flow is too heavy. Water inlet hose is loose at supply hose or Adjust water flow. Tighten connections and/ inlet hose is loose at bulkhead fitting. or replace hose washers.
  • Página 7 3. Once the front flap is moved, grasp the right pad and tilt out at a 90° angle. (See Figure 2) 4. Pull the pad up to remove from unit. Repeat for other Figure 3 pads. (See Figure 3) 1-800-295-5510 uline.com PAGE 7 OF 21 0621 IH-3030...
  • Página 8 H-3030, H-3784 800-295-5510 uline.mx ENFRIADOR EVAPORATIVO INTRODUCCIÓN ¿QUÉ ES EL ENFRIAMIENTO EVAPORATIVO? ¿Cómo se produce el enfriamiento? Para que el agua se evapore, se necesita calor (energía). De hecho, la Al intentar comprender qué es el enfriamiento evaporación de un galón de agua requiere casi 8,700 evaporativo, puede que sea mejor pensar en el aire BTU (Unidad Térmica Británica).
  • Página 9 CONECTAR EL AGUA Y LA ELECTRICIDAD Una vez que se haya llenado el tanque del colector, el CONEXIÓN DEL AGUA (Solo se aplica a H-3030) flujo de agua debería detenerse y las conexiones de entrada pueden ser inspeccionadas visualmente para NOTA: La unidad debe estar en posición...
  • Página 10 CONTINUACIÓN DE CONFIGURACIÓN CONEXIÓN ELÉCTRICA Al hacer conexiones eléctricas, asegúrese de cumplir con los códigos locales y nacionales. Para usar solo NOTA: ¡La unidad debe estar en posición vertical con Receptáculos con protección GFCI (de tierra). con los paneles de enfriamiento instalados! Consulte el código de barras de la etiqueta del Esta unidad utiliza un único cable eléctrico e producto ubicado en el lado de la unidad para ver los...
  • Página 11 A diario, la bomba deberá apagarse Puede comprar adicionalmente cajas de tratamiento aproximadamente 15 minutos antes de apagar de minerales solicitando en Uline el modelo número el ventilador. Esto permitirá que los paneles de H-6108. enfriamiento se sequen y ayudará a alargar su vida útil,...
  • Página 12 SOLUCIÓN DE PROBLEMAS SOLUCIÓN DE PROBLEMAS Si entiende completamente todos los sistemas de la unidad y cómo dependen unos de otros, resulta Los problemas más comunes que surgen en la unidad muchos más sencillo definir y resolver cualquier están relacionados con el funcionamiento. La unidad problema.
  • Página 13 CONTINUACIÓN DE SOLUCIÓN DE PROBLEMAS SISTEMA DE ENTRADA DE AGUA PROBLEMA REVISAR SOLUCIÓN El piso cercano a la unidad está mojado. El La manguera de entrada de agua está Ajuste el flujo de agua. Apriete las flujo de agua es demasiado fuerte. suelta en la manguera de suministro o la conexiones y/o reemplace las rondanas manguera de entrada está...
  • Página 14 ángulo de 90°. (Vea Diagrama 2) 4. Tire del panel hacia arriba para sacarlo de la unidad. Repita la operación con los otros paneles. (Vea Diagrama 3) 800-295-5510 uline.mx PAGE 14 OF 21 0621 IH-3030...
  • Página 15 H-3030, H-3784 1-800-295-5510 uline.ca REFROIDISSEUR PAR ÉVAPORATION INTRODUCTION QU'EST-CE QUE LE REFROIDISSEMENT PAR S'agit-il d'une éponge de 10 ˚C (50 ˚F) ou d'une éponge de 26,7 ˚C (80 ˚F)? Une éponge de 26,7 ˚C (80 ˚F) ÉVAPORATION? absorbera plus d'eau à un taux d'humidité de 50 % qu'une éponge de 10 ˚C (50 ˚F).
  • Página 16 Retirez les RACCORDEMENT D'EAU (s'applique seulement tampons de refroidissement.* Lorsque le réservoir à H-3030) collecteur est rempli, le débit d'eau doit s'arrêter et les REMARQUE : L'unité doit être en position raccordements d'entrée peuvent alors être vérifiés pour verticale et de niveau.
  • Página 17 MISE EN PLACE SUITE *Consultez la page 21 pour plus de détails stagnante près du cordon ou de l'utilisateur. L'utilisation d'une barre multiprise n'est pas recommandée. RACCORDEMENT ÉLECTRIQUE Lorsque vous effectuez des raccordements électriques, REMARQUE : L'unité doit être en position assurez-vous d'être en conformité...
  • Página 18 ENTRETIEN QUOTIDIEN évaporation. Des boîtes additionnelles sont disponibles en La pompe doit être éteinte quotidiennement environ commandant le nombre de modèle Uline H-6108. 15 minutes avant d'éteindre le ventilateur. Cela permet aux tampons de refroidissement de sécher et d'assurer ENTREPOSAGE également leur longévité...
  • Página 19 DÉPANNAGE DÉPANNAGE Si vous maîtrisez le fonctionnement de tous les systèmes de l'unité et la façon dont ils interagissent, il sera alors Les problèmes les plus courants liés à l'unité sont des beaucoup plus simple de définir et de résoudre les problèmes de fonctionnement.
  • Página 20 DÉPANNAGE SUITE SYSTÈME DE PRISE D'EAU PROBLÈME VÉRIFIER SOLUTION Le plancher près de l'unité est mouillé. Le débit Le tuyau de la prise d'eau est lâche au niveau Réglez le débit d'eau. Serrez fermement d'eau est trop puissant. du tuyau d'alimentation ou le tuyau d'entrée les raccordements et/ou remplacez les est lâche au niveau du raccord de traversée.
  • Página 21 3. Une fois le rabat avant déplacé, saisissez le tampon droit et inclinez-le à un angle de 90°. (Voir Figure 2) 4. Tirez le tampon vers le haut pour le retirer de l'unité. Répétez cette opération pour les autres tampons. (Voir Figure 3) 1-800-295-5510 uline.ca PAGE 21 OF 21 0621 IH-3030...

Este manual también es adecuado para:

H-3784