Assigned Torque Value for Terminal
Wire Size (AWG)
2-14 Copper, 2-8
Aluminum
NEMA
RECEPTACLE
®
STEP 1:
Loosen (DO NOT REMOVE)
the two Torx head
screws on the twist lock NEMA
STEP 2:
Use a flat blade screwdriver to rotate the
center section of the receptacle until NORTH
.
indicator faces north.
STEP 3:
Retighten the two Torx head screws to 15
in-lbs torque..
STEP 4:
Insert the pins on the base of the photocell
into the slots in the receptacle on top of the
fixture. NOTE: One pin is wider than the other
two pins and must be inserted into the widest
slot. Do NOT force pins into receptacle if pins
are not properly oriented with slots
ELECTRICAL CONNECTIONS
STEP 1:
NOTE: Terminal block accommodates 6-16 AWG wire.
Make the following Electrical Connections to the terminal block:
a. For 120 Vac / 277 Vac, Connect the supply Vin lead to the voltage
supply Line position of the terminal block
(Hot 1 for 208 Vac / 240 Vac wiring).
a. For 120 Vac / 277 Vac, Connect the supply common lead to the neutral
supply position of the terminal block
(Hot 2 for 208 Vac / 240 Vac wiring).
b. Connect the green or green/yellow ground lead to the green wire
(ground) position of the terminal block.
NOTE: Dimming capabilities are accessible through the 7-pin NEMA
receptacle when used with a photo control with dimming capabilities.
Terminal block will accommodate 6-16 AWG.
STEP 2:
Push excess supply wires into pole.
STEP 3:
Close cover, making sure that no wires are pinched.
© 2022 Cree Lighting, A company of IDEAL INDUSTRIES. All rights reserved. For informational purposes only. Content
is subject to change. See www.creelighting.com/warranty for warranty and specifications. Cree
registered trademarks and the Cree SmartCast Technology logo is a trademark of Cree, Inc.
2 of 2
Block Screws
AWG
In.-lbs.
2-3
50
4-6
45
8
40
10-14
35
STEP 5:
Once pins are inserted into receptacle,
rotate photocell in a clockwise direction
approximately 1/8 turn to lock it in place.
receptacle.
®
FCC NOTICE
CAUTION: Changes or modifications not ex-
pressly approved could void your authority to
use this equipment.
This device complies with part 15 of the FCC
Rules. Operation is subject to the following
two conditions: (1) This device may not cause
harmful interference, and (2) this device must
accept any interference received, including
interference that may cause undesired
operation.
LINE
OR HOT 1
GREEN
NEUTRAL
OR HOT 2
®
and the Cree logo are
®
www.creelighting.com
This equipment has been tested and found
to comply with the limits for a Class A
digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide
reasonable protection against harmful
interference when the equipment is operated
in a commercial environment. This equipment
generates, uses, and can radiate radio
frequency energy and, if not installed and used
in accordance with the instruction manual,
may cause harmful interference to radio
communications. Operation of this equipment
in a residential area is likely to cause harmful
interference in which case the user will be
required to correct the interference at his own
expense.
CAN ICES-005 (A)/NMB-005 (A)
TERMINAL
LUMINAIRE
BLOCK
LINE-BLACK
GROUND-GREEN
NEUTRAL-WHITE
LPN05497X0001A0_B