10
1. Sensitivity
Sensitivity can be adjusted by
selecting the combination on
the DIP switches for different
applications.
Wall mounting (m)
6
5
4
3
2
1
1
2
1
2
3
4
5
6
Detection area for turning ON
Detection area to pervent
from turning OFF
The light keeps off during daytime even
when movement is detected. (Ambient
lux level is above preset daylight
threshold)
www.schreder.com
100%
75%
50%
25%
10%
2. Hold-time
Hold-time refers to the time
period that the light remains
100% on if no more movement
is detected.
Warning!
3
4
5
6
- Keep the luminiare 4m away from metal shelves or other reflective metal surfaces.
- Keep the luminaire away from industrial fan or any other industrial machinery that
may release vibration.
- Keep the luminaire at least 10m away from public mobile base station.
- Installation height is max. 4m.
- In case of outdoor usage wind, rain and moving objects can cause false triggering.
With movement and insufficient ambient
lux level, the light is triggered on by the
detector.
30min
20min
6min
90s
30s
10s
3. Daylight threshold
Different daylight threshold can
be preset on DIP switches.
Light will always turn on upon
movement if daylight sensor is
disabled.
Disabled
50lux
30lux
10lux
5lux
If there is no more movement, the light
turns off automatically after hold-time
preset.
3/4