• To maintain optimum performance,
clean the boiler every 10/20 uses
depending on the amount of limestone in
the water.
• Disconnect the appliance and let it
cool down for at least 2
hours.
• After the appliance refrigeration enough
put up one side of the cleaning valve
(11),
forced to rotate counterclockwise the
cleaning valve (Fig.5) (do not lie fiat the
appliance when you open the cleaning
valve,
otherwise the water will
leakage).
CAUTION! Never attempt to open the
cleaning valve ( 11) while the boiler is
under pressure.
CAUTION: do not pour more than
200ml water into the boiler. Pour water
slowly, being careful not to let it
overflow,
as this could damage the
appliance.
• Rinse out the boiler and pour the water
away into the sink or into a container for
collecting dirty
water.
• If the water is very
dirty,
repeat the
operation until it is clean.
• Checking that the seal is present and
that the cap is screwed on properly.
• Fill the water tank again.