Descargar Imprimir esta página

Hella Gutmann MT-HV Manual De Instrucciones página 54

Ocultar thumbs Ver también para MT-HV:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 111
General information
Technical data of the MT-HV
Ranges
EN
Voltage
Insulation resistance measurement
Resistance (service disconnect plug)
Potential equalization measurement
High-Voltage Test Leads
Red
black
54
Measuring range: ± 1000 V DC
Resolution: 0.1 V
Precision: ± (1 % of reading + 2 digits)
Measuring range: 10k to 10GΩ
Test voltage: variably adjustable to 1000 V DC in steps of 10 V
Resolution: 0.1
Precision: ± (3 % of reading + 3 digits)
Measuring range: 0 to 10 Ω
Resolution: 0.01 Ω
Measuring current: 200 mA
Precision: ± (2.5 % of reading + 4 digits)
Measuring range: 0 to 10 Ω
Resolution: 0.01 Ω
Measuring current: 200 mA
Precision: ± (2.5 % of reading + 4 digits)
Length: 1500 mm
Handpiece with function button
With 4 mm test connection for manufacturer-specific test
adapters
incl. plug-on measuring probe
Length: 1500 mm
Handpiece
With 4 mm test connection for manufacturer-specific test
adapters
incl. plug-on measuring probe
MT-HV

Publicidad

loading