AXIS TQ6905-E Washer Kit
Specifications
Operating Conditions
Maximum temperature
60°C (140°F)
Power Consumption
AC
230 VAC
120 VAC
24 VAC
Fuses
AXIS Washer Kit comes with a pre-mounted fuse for 230V in position FUS1. If the power supply
is different, remove the fuse from position FUS1 and insert it in correct position (FUS2 or FUS3).
See table.
CAUTION
• Electrical connections must be performed with the power supply disconnected and the
circuit-breaker open.
• When commencing installation make sure that the specifications for the power supply
correspond with those required by the device.
Voltage
230 VAC
120 VAC
24 VAC
See Hardware overview on page 10 for fuse positions.
NO
NO
NO TICE
TICE
TICE
• Make sure that the power source and connecting cables are suitable for the power
consumption of the system.
Minimum temperature
Antifreeze liquid in solution
(full performance)
-10°C (14°F)
Current Consumption
0.3 A
0.6 A
1.8 A
Fuse holder
FUS1 (pre-mounted)
FUS2
FUS3
20
Minimum temperature
Antifreeze liquid in solution
(reduced performance)
-25°C (-13°F)
Power Line Frequency
50/60 Hz
50/60 Hz
50/60 Hz