set
room
set
room
H: When the KEY-LOCK
light lights up, the
childproof lock has been
activated.
4
38
f - 1
Faulty burner thermistor.
e - 2
Starting problems.
e - 5
Tipping-over protection.
e - 6
Poor burning.
e - 7
Room temperature
above 28°C.
e - 8
Defective booster.
e - 9
Air filter dirty; or
Fuel pump dirty.
The heater has been in operation
continuously for a period of 48 hours
and has turned itself off automatically.
-- : --
Out of fuel.
(& blinking
FUEL-light)
-- : --
Too little ventilation.
(& blinking
VENT-light)
Always contact your dealer for any malfunctioning not listed above.
AUTOMATIC DEACTIVATION
This heater is fitted with a safety system that ensures that it switches off
automatically after 48 hours continuous operation. The following will then appear
in the display:
the
button
(see section D).
AUTOMATIC CLEANING MODE
When te heater has been burning continuously for two hours at its highest
setting, the burner will automatically start an autoclean procedure. The display
will show the autocleaningcode cl:05 running back to cl:00. The procedure takes 5
minutes, during which the heater will burn at its lowest setting, while the burner
autocleans. When the burner is clean again, the heater will automatically switch
back to the highest setting again.
I
CHILDPROOF LOCK
The childproof lock can be used to prevent children accidentally changing the
heater settings. When the heater is burning and the childproof lock is on, the
heater can only be switched off. Other functions are blocked then. If the heater
has already been switched off, the childproof lock also prevents accidental
ignition of the heater.
Activate the childproof lock by pressing the appropriate key
for more than 3 seconds. The KEY-LOCK indicator light will light up (Fig. H),
indicating that the childproof lock has been activated. Switch off the childproof lock
by pressing the key
J
THE 'FUEL' INDICATOR LIGHT
When the FUEL indicator light lights up, there is enough fuel left for another 10
minutes of heater use. The count-down of the remaining heating time can be seen
in the information display
warning you to refill the removable tank. If you do not react, the heater will
. If desired, you can switch the heater on again by pressing
and holding it down for more than 3 seconds once again.
(Fig. I). Every two minutes an alarm signal is sounded,
Contact your dealer.
Contact your dealer.
Re-ignite the heater.
Contact your dealer.
If necessary,
re-ignite the heater.
Contact your dealer.
Clean filter.
Contact your dealer.
Switch the heater back on.
Refill removable tank.
Ventilate better.
and holding it down