● OPERATING INSTRUCTIONS ●
S
PECIFICATIONS
Indoor
Model
Outdoor
Function
Power supply
Capacity
Input
Indoor
Weight
Outdoor
Refrigerant fi lling capacity (R32)
Indoor
IP code
Outdoor
LP ps
Permissible excessive
operating pressure
HP ps
Indoor (Super High/High/Med./Low/
EN
Silent)
Noise level (SPL)
Outdoor
Indoor specifi cation for multi connection
Model
Indoor
Cooling
Capacity
Heating
Input
Noise level
Super High/High/Med./Low/Silent
(Sound power level)
Guaranteed operating range
Upper limit
Cooling
Lower limit
Upper limit
Heating
Lower limit
Wi-Fi
interface
®
Model
Input Voltage
Power consumption
Size H×W×D (mm)
Weight (g)
Transmitter power level (MAX.)
RF channel
Radio protocol
Encryption
Authentication
Software Version
For Declaration of Conformity, please go to the website below.
http://www.mitsubishielectric.com/ldg/ibim/
EN-6
kW
kW
kg
kg
kg
MPa
MPa
dB(A) 46/41/36/27/19 49/46/39/31/19 47/42/36/27/19 52/49/42/33/19 48/45/40/34/28 54/51/45/36/28
dB(A)
REGULATION (EU) 2016/2281
Sensible
kW
Latent
kW
kW
kW
dB(A)
Indoor
Outdoor
32°C DB
46°C DB
23°C WB
—
21°C DB
-10°C DB
15°C WB
—
27°C DB
24°C DB
—
18°C WB
20°C DB
-25°C DB
—
-26°C WB
MAC-577IF2-E
DC12.7 V (from indoor unit)
MAX. 2 W
73.5×41.5×18.5
46 (including cable)
20 dBm @IEEE 802.11b
1ch ~ 13ch (2412~2472 MHz)
IEEE 802.11b/g/n (20)
AES
WPA2-PSK
XX.00
MSZ-FT25VGK
MUZ-FT25VGHZ
Cooling
Heating
Cooling
2.5
3.2
0.58
0.76
34
0.85
46
49
MSZ-FT25VGK
2.37
0.13
3.20
0.039
60/55/50/41/33
Note:
Rating condition
Cooling — Indoor:
Heating — Indoor:
DB: Dry Bulb
WB: Wet Bulb
W
HEN YOU THINK THAT
TROUBLE HAS OCCURRED
In the following cases, stop using the air conditioner and consult your dealer.
• When water leaks or drips from the indoor unit.
• When the operation indicator lamp blinks.
• When the breaker trips frequently.
• The remote control signal is not received in a room where an electronic ON/
OFF type fl uorescent lamp (inverter-type fl uorescent lamp, etc.) is used.
• Operation of the air conditioner interferes with radio or TV reception. An ampli-
fi er may be required for the affected device.
• When an abnormal sound is heard.
• When any refrigerant leakage is found.
MSZ-FT35VGK
MSZ-FT50VGK
MUZ-FT35VGHZ
MUZ-FT50VGHZ
Heating
Cooling
~ /N, 230 V, 50 Hz
3.5
4.0
5.0
0.91
1.02
1.63
10
40
0.95
IP 20
IP 24
2.77
4.17
49
52
51
MSZ-FT35VGK
2.80
0.70
4.00
0.040
60/55/50/41/33
27°C DB, 19°C WB
Outdoor: 35°C DB
20°C DB
Outdoor: 7°C DB, 6°C WB
Heating
5.0
1.30
54