• Make sure that the new electric coil voltage
corresponds to the electrical installation voltage.
• Position the new Tramontina electrical coil on the
pins. Make sure they only fit in one position.
• Push the electrical coil down on the electrical box
pins, until the limiting pins touch the diaphragm disc.
• Position the diaphragm on the shower body
observing the position of the ground wire and
fittings.
• Make sure the electrical coil box is in place and the
"off" position is aligned with the central line on
the shower.
• Manually screw the top nut on, holding the shower
body. Make sure the top nut is firmly tightened.
• Turn on the water supply, Llet the water run for a
few minutes.
• Turn on the circuit breaker or mains switch.
• Select temperature and turn on the tap. Shower
should turn on automatically.
7. Operation
• After installing and before connecting the shower
to on the power grid, let water run until obtaining
reaching a normal flow. This procedure is extremely
important to prevent damage to the electrical coil
due to the lack of water in the heating chamber.
• Turn the mains switch or circuit breaker on again.
Adjust the temperature selector to the "hot" or
"warm" position. The appliance switches itself on
automatically when the faucet is on. Temperature
can be controlled through the tap, increasing or
reducing the water flow.
IMPORTANT
• For user's safety and to extend the life of the
Senseday Shower, turn off the water before
changing temperature.
• Assemble the hand-held shower by attaching it to
the hose. To use it, pull to turn it on and push to
shut it off.
• To clean the appliance, use only a damp cloth.
Never use abrasive products.
• Before proceeding to cleaning or maintenance
work, shut the power off through the circuit
breaker.
• For your safety, electrical installation and earthing
grouding for this product must be executed by
qualified persons.
• Do not connect any accessories not produced or
authorized by Tramontina to this appliance.
• Any maintenance work needed must be executed
by authorized representatives.
• If the electrical coil is burnt, it must be replaced by
a new one of the same make and model. Only use
Tramontina original parts.
• Do not forget to shut the power off before
replacing the electrical coil.
• To avoid electrical hazards, the electric power cord,
as well as the other components of the appliance,
should only be replaced by the technical assistance
service.
English
8. Troubleshooting
PROBLEM
LIKELY CAUSE
Temperature selector
is switched to "off"
position.
Shower won't
turn on
Low water pressure.
There's no
The water supply is
water coming
off or there is air in
out of the
the pipes.
Shower
Inadequate wiring.
The Shower
does not
Low electrical
heat up
tension.
High water pressure/
flow.
More than one appli-
ance switched on to
the shower circuit.
The current of the
The circuit
device is higher than
breaker is
the rated current of
unarmed
the circuit breaker.
The circuit breaker
terminals are
warning up.
Low water pressure/
flow.
The Shower
heats up too
Temperature selector
much
is switched to "hot"
position.
3
SOLUTION
Set the selector to any
heating up position.
Check the minimum
height between the water
tank and the appliance.
Increase water flow.
Turn on the water supply
and faucets related to the
system and let water run
until the air is removed,
with the appliance in the
"off" position.
Please contact a qualified
Professional to verify
whether the conductors
are in compliance with
the ones specified in this
manual.
Please contact a qualified
Professional to verify whether
the electrical tension is in
accordance with nominal
values 110V
/ 127V
or
˜
˜
220V
/ 230V
.
˜
˜
If it is, please contact your local
sales representative.
Reduce water pressure/
flow by turning tap off or
adding a reducer.
Provide an exclusive
electric circuit for the
shower.
Check that the wiring is
adequate, and if it is not
replace it with the circuit
breaker.
Retighten the terminals,
if the problem persists
change the circuit breaker
for another with the same
nominal value.
Increase water pressure/
flow by turning tap on or
removing the reducer.
Adjust the Selector to a
pleasant temperature.

Publicidad

loading