T EC HN IC A L I N F ORMAT IO N
Water pressure
Recommended
Maximum
Hot water temp.
Recommended
Maximum
Flow rate - 34960xx1
tub filler
handshower
Flow rate - 39451xx1
tub filler
handshower
* Please know and follow all applicable local plumbing
codes when setting the temperature on the water heater.
I NSTA LL AT I O N CO N SID E R ATI ONS
⁄ For best results, Hansgrohe recommends that this unit
be installed by a licensed, professional plumber.
⁄ Please read over these instructions thoroughly
before beginning installation. Make sure that you
have all tools and supplies needed to complete the
installation.
Thi s tr im is fo r use wit h rou gh val ve
10 45 2181 (n o t in clude d) .
⁄ This unit is not anti-scald. If required by local code,
install in combination with an approved remote pres-
sure balance valve or other approved device.
⁄ Protection against backflow is provided by a check
valve and by an automatically resetting diverter.
15 - 75 PSI (0.1 - 0.5 MPa)
145 PSI (1 MPa)
120°-140° F (48° - 60° C)*
158°F (70° C)*
5.8 GPM (22 L/min) @ 44 PSI
max. 1.75 GPM (6.6 L/min)
5.8 GPM (22 L/min) @ 44 PSI
max. 2.0 GPM (7.6 L/min)
E N G L I S H
⁄ 34960xx1 only: This showerhead is for use with an
automatically compensating valve rated at 1.3 GPM
(4.9 L/min) or less.
⁄ 39451xx1 only: This showerhead is for use with an
automatically compensating valve rated at 1.5 GPM
(5.7 L/min) or less.
⁄ To prevent scald injury, the maximum output tempera-
ture of the shower mixing valve must be no higher
than 120°F. In Massachusetts, the maximum output
temperature can be no higher than 112°F.
⁄ Keep this booklet and the receipt (or other proof
of date and place of purchase) for this product in
a safe place. The receipt is required should it be
necessary to request warranty parts.