Descargar Imprimir esta página

Buffalo GL346 Manual De Instrucciones página 5

Ocultar thumbs Ver también para GL346:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 27
Emptying the Appliance
GL346/GL347/GL348/GL349/CU547/
CU548/CU549/CJ549:
Drain the appliance by using the tap to empty.
HF150/HF151/HF152/HF153:
Drain the appliance with hand over the hand
sensor until empty.
Thermal Cut-Out Reset
This appliance is fitted with a Thermal Cut-Out
safety feature. Should the temperature exceed safe
levels the appliance will automatically cut power.
The Safety Cut-out switch is located on the
underside of the appliance.
To reset the appliance:
1. Empty the appliance and allow to cool.
2. Press the reset button until it clicks.
WARNING: Ensure the appliance has cooled
down and is empty before resetting the
switch, as it may need to be tipped slightly
to gain access to the switch.
3. The appliance is now reset and can be used as
normal.
Cleaning, Care &
Maintenance
Always turn off and disconnect the
appliance from the power supply before
cleaning and descaling.
Let the appliance cool down then empty.
Troubleshooting
A qualified technician must carry out repairs if required.
Fault
The unit is not working
GL346-GL349_HF150-HF153_CU547-CU549_CJ549_ML_A5_v7_20230105.indb 5
GL346-GL349_HF150-HF153_CU547-CU549_CJ549_ML_A5_v7_20230105.indb 5
Descaling
For the best water quality, Buffalo recommend that
a water filter is installed to the mains water supply,
particularly in hard water areas. Doing so will
reduce the build up of limescale and contaminants
in the water tank thus maintaining energy
efficiency and prolonging the life of the appliance.
To de-scale the appliance:
1. Pour a solution of de-scaler and water into the
2. Brush the interior gently with a soft bristled
3. Discard the solution collected in the jug.
4. Fill the appliance with clean water and turn
5. The appliance is now ready for use.
Probable Cause
The unit is not switched on
Plug or lead is damaged
Fuse in the plug has blown
Mains power supply fault
Thermal fuse has activated
Do not use jet/pressure washers to clean the
appliance.
Use soapy water and a damp cloth to clean the
exterior of the appliance.
Dry thoroughly after cleaning.
appliance.
brush.
back On to flush out the system. Flush out the
system thoroughly to remove any de-scaler
residue.
Note: Use a suitable de-scaler and always
follow the instructions on the container.
BUFFALO recommend that this appliance is
de-scaled every 3 months or more often in
hard water areas.
IMPORTANT: Failure to de-scale or
maintain will invalidate your guarantee.
Solution
Check the unit is plugged in correctly and
switched on
Replace Plug or lead
Replace the fuse
Check mains power supply
Reset Thermal fuse
EN
5
2023/1/5 16:41
2023/1/5 16:41

Publicidad

loading