ERROR
CODES
01H
02H
04H
06H
07H
32
2
ERROR
CAUSES
CODES
LE1
Voltage of inverter
power is low.
NTCF
Temperature sensor of
inverter is abnormal.
OC
Inverter outputs
overcurrent.
OE
Inverter is overcurrent.
FOT
IGBT on inverter
is abnormal.
POSSIBLE
CORRECTIVE
CAUSES
MEASURES
Voltage of utility power
Check if utility power
is too low.
supply matches
voltage of inverter.
Inverter is broken.
Replace inverter.
Filter is broken.
Replace filter.
Choke is broken.
Replace choke.
Temperature
Replace inverter.
sensor of inverter
is broken.
Running belt/deck is
Add lubricant to
aging.
running belt.
Running belt/deck is
Replace running belt
broken.
and deck.
Inverter is broken.
Replace inverter.
Wire of brake
Check wires.
resistor is
disconnected.
Brake resistor is broken.
Replace brake resistor.
Inverter is broken.
Replace inverter.
IGBT on inverter is
Replace inverter.
abnormal.
ADDITIONAL
INFO
Inspect whether
the utility power is
110/220V.